English
Language : 

L7583A Datasheet, PDF (7/20 Pages) Agere Systems – Line Card Access Switch
Data Sheet
February 2001
L7583A/B/C/D Line Card Access Switch
Electrical Characteristics (continued)
Table 9. Ring Return Switch, 7
Parameter
OFF-state Leakage
Current:
+25 °C
+85 °C
–40 °C
dc Current Limit
Dynamic Current Limit
(t = <0.5 µs)
ON-resistance
ON-state Voltage*
Isolation:
+25 °C
+85 °C
–40 °C
dV/dt Sensitivity†
Test Condition
Measure Min Typ Max Unit
Vswitch (differential) = –320 V to Gnd
Vswitch (differential) = –60 V to +260 V
Vswitch (differential) = –330 V to Gnd
Vswitch (differential) = –60 V to +270 V
Vswitch (differential) = –310 V to Gnd
Vswitch (differential) = –60 V to +250 V
Vswitch (on) = ±10 V
Break and loop switches in OFF state; ring return
switch ON; apply ±1000 V at 10/1000 µs pulse;
appropriate secondary protection in place
Iswitch (on) = ±0 mA, ±10 mA
Iswitch = ILIMIT @ 50 Hz/60 Hz
Iswitch — — 1 µA
Iswitch — — 1 µA
Iswitch — — 1 µA
Iswitch — 200 — mA
Iswitch — 2.5 — A
∆ VON
VON
— — 100 Ω
— — 130 V
Vswitch (both poles) = ±320 V, Logic inputs = Gnd
Vswitch (both poles) = ±330 V, Logic inputs = Gnd
Vswitch (both poles) = ±310 V, Logic inputs = Gnd
—
Iswitch
Iswitch
Iswitch
—
— — 1 µA
— — 1 µA
— — 1 µA
— 200 — V/µs
* This parameter is not tested in production. Choice of secondary protector should ensure this rating is not exceeded.
† Applied voltage is 100 Vp-p square wave at 100 Hz.
Table 10. Ringing Access Switch, 8
Parameter
OFF-state Leakage
Current:
+25 °C
+85 °C
–40 °C
ON Voltage
Ring Generator Cur-
rent During Ring
Steady-state Current†
Surge Current†
Release Current
ON-resistance
Isolation:
+25 °C
+85 °C
–40 °C
dV/dt Sensitivity‡
Test Condition
Measure Min Typ Max Unit
Vswitch (differential) = –255 V to +210 V
Vswitch (differential) = +255 V to –210 V
Vswitch (differential) = –270 V to +210 V
Vswitch (differential) = +270 V to –210 V
Vswitch (differential) = –245 V to +210 V
Vswitch (differential) = +245 V to –210 V
Iswitch (on) = ±1 mA
VCC = 5 V
INRING = 1
INTESTin = 0
INTESTout = 0
—
—
—
Iswitch (on) = ±70 mA, ±80 mA
Iswitch — — 1 µA
Iswitch — — 1 µA
Iswitch — — 1 µA
—
—— 3 V
IRING-
—
* — mA
SOURCE
—
—
—
∆ VON
— — 150 mA
—— 2 A
— 500 — µA
— — 12 Ω
Vswitch (both poles) = ±320 V, Logic inputs = Gnd
Vswitch (both poles) = ±330 V, Logic inputs = Gnd
Vswitch (both poles) = ±310 V, Logic inputs = Gnd
—
Iswitch
Iswitch
Iswitch
—
— — 1 µA
— — 1 µA
— — 1 µA
— 200 — V/µs
* At the time of publication of this data sheet, the current device design will be a nominal 4 mA. Devices are being redesigned to reduce this
current to less than 2 mA nominally. Consult your Lucent Technologies Microelectronics Group account executive for additional details.
† Choice of secondary protector and series current-limit resistor should ensure these ratings are not exceeded.
‡ Applied voltage is 100 Vp-p square wave at 100 Hz.
Lucent Technologies Inc.
7