English
Language : 

Z90349 Datasheet, PDF (8/8 Pages) Zilog, Inc. – DIGITAL TELEVISION CONTROLLER IN-CIRCUIT EMULATOR (ICE) DEVICE
Zilog
PRELIMINARY
AC CHARACTERISTICS
TA = 0°C to + 70°C; VCC = 4.5 V to 5.5 V; FOSC = 32.768 KHz
Symbol
TPC
TRC,TFC
T POR
D
Parameter
Input Clock Period
Clock Input Rise and Fall
Power On Reset Delay
Min
Max
16
100
0.8
Typical Units
32
µs
12
µs
1.2
s
Z90349/Z90348
Note
Depends on Crystal
AC CHARACTERISTICS*
T
A
=
0°C
to
+
70°C;
V
CC
=
4.5
V to 5.5 V; F = 32.768 KHz
OSC
Symbol
Parameter
TWRES
TDHS
TV
DS
TE
DS
Power-On Reset Min. Width
H_Sync Incoming Signal Width
V_Sync Incoming Signal Width
Time Delay Between Leading Edge
of V_Sync and H_Sync in Even Field
TDOS
T HV
WS
Time Delay Between Leading Edge
of H_Sync in Odd Field
H_Sync/V_Sync Edge Width
Notes:
All timing of the I2C bus interface are defined by related specifications of
the I2C bus interface.
Min
5.5
0.15
–12
20
Max
5TPC
12.5
1.5
+12
44
2.0
Typical
11
1.0
0
32
0.5
Units
µs
µs
ms
µs
µs
µs
© 1997 by Zilog, Inc. All rights reserved. No part of this document
may be copied or reproduced in any form or by any means
without the prior written consent of Zilog, Inc. The information in
this document is subject to change without notice. Devices sold
by Zilog, Inc. are covered by warranty and patent indemnification
provisions appearing in Zilog, Inc. Terms and Conditions of Sale
only. Zilog, Inc. makes no warranty, express, statutory, implied or
by description, regarding the information set forth herein or
regarding the freedom of the described devices from intellectual
property infringement. Zilog, Inc. makes no warranty of mer-
chantability or fitness for any purpose. Zilog, Inc. shall not be
responsible for any errors that may appear in this document.
Zilog, Inc. makes no commitment to update or keep current the
information contained in this document.
Zilog’s products are not authorized for use as critical compo-
nents in life support devices or systems unless a specific written
agreement pertaining to such intended use is executed between
the customer and Zilog prior to use. Life support devices or
systems are those which are intended for surgical implantation
into the body, or which sustains life whose failure to perform,
when properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result in
significant injury to the user.
Zilog, Inc. 210 East Hacienda Ave.
Campbell, CA 95008-6600
Telephone (408) 370-8000
Telex 910-338-7621
FAX 408 370-8056
Internet: http://www.zilog.com
8
CP97TEL2600