English
Language : 

Z02205 Datasheet, PDF (8/30 Pages) Zilog, Inc. – MODEM CONTROLLER IDEAL FOR LOW POWER CONSUMPTION, SMALL SIZE REQUIREMENTS
Z02205
Modem Controller
ZiLOG
VCC
TA = 0° C to +70°C
Sym
Parameter
Note [3]
Min
Typical [1]
Max
@ 25°C Units
Conditions
Notes
IIR
Reset Input
5.5V
–20
–180
–85
µA
Current
ICC
Supply Current 5.5V
25
20
mA @ 16 MHz
4
ICC1
Standby Current 5.5V
(HALT Mode)
8
3.7
mA VIN = 0V, VCC
4
@ 16 MHz
ICC2
Standby Current 5.5V
(STOP Mode)
10
4
µA VIN = 0V, VCC WDT is 6,11
not Running
5.5V
800
600
µA VIN = 0V, VCC WDT is 6,11,
Running
13
VICR
Input Common
5.5V
0
VCC–1.0V
V
10
Mode
Voltage Range
IALL
Auto Latch Low 5.5V
1.4
15
Current
5
µA 0V < VIN < VCC
9
IALH
Auto Latch High 5.5V
–1.0
–8
Current
–6
µA 0V < VIN < VCC
9
VLV
VCC Low
Voltage
Protection
Voltage
2.8
V 4 MHz max Int. CLK
7
Freq.
2.2
3.1
2.8
6 MHz max Int. CLK 7,13
Freq.
VOH
Output High
Voltage
5.0V
VCC–0.4
4.8
V IOH = –0.5 mA
(Low EMI
Mode)
VOL
Output Low
Voltage
5.0V
0.4
0.1
V IOL = 1.0 mA
(Low EMI
Mode)
Notes:
1. Typicals at VCC = 5.0V.
2. GND = 0V.
3. The VDD voltage specification of 5.5V guarantees 5.0V ±0.5V with typicals at VCC–5.0V.
4. All outputs unloaded, I/O pins floating, inputs at rail.
5. CL1 = CL2 = 10 pF.
6. Same as note [4] except inputs at VCC.
7. The VLV voltage increases as the temperature decreases and will overlap lower VCC operating region.
8. Standard Mode (not Low EMI).
9. Auto Latch (Mask Option) selected.
10. For analog comparator, inputs when analog comparators are enabled.
11. Clock must be forced Low, when XTAL1 is clock-driven and XTAL2 is floating.
12. Excludes clock pins.
13. 0°C to 70°C (standard temperature).
6
PS001000-MOD0599