DC CHARACTERISTICS
VCC = 4.75 V to 5.25V @ 0°C to +70°C
Symbol Parameter
Min Max
V
Clock Input High Voltage
3.8 V
CH
CC
VCL
Clock Input Low Voltage
–0.3 0.8
V
Input High Voltage
2.0 V
IH
CC
V
Input Low Voltage
–0.3 0.8
IL
V
Reset Input High Voltage
3.8 V
RH
CC
V
Reset Input Low Voltage
–0.3 0.8
RL
V
Output High Voltage
2.0
OH
Output High Voltage
2.4
V
Output Low Voltage
OL
I
Input Leakage
IL
IOL
Output Leakage
0.8
–10 10
–10 10
I
Reset Input Current
–50
IR
I
V Supply Current
150
CC
CC
Notes:
† Typical @ 25°C
1 A combined total of four I/O pins from Ports0, 1, and 2 may be used to sink 10
ma at 0.8 Volts (maximum two pins per port). These may be used for LEDs
or as general purpose outputs requiring high sink current.
Z8602
CPS DC-4087-02
Typ† Unit Condition
V Driven by External Clock Generator
V Driven by External Clock Generator
V
V
V
V
V
I=
OH
–250
µA
(Port
2
only)
V
I=
OH
–250
µA
(Port
3
only)
V I = +4.0 mA (See Note 1 below.)
OL
µA
V = 0V, 5.25V
IN
µA VIN = 0V, 5.25V
µA
V = 0V, 5.25V
IN
135 mA
© 1993 by Zilog, Inc. All rights reserved. No part of this document may
be copied or reproduced in any form or by any means without the prior
written consent of Zilog, Inc. The information in this document is subject
to change without notice. Devices sold by Zilog, Inc. are covered by
warranty and patent indemnification provisions appearing in Zilog, Inc.
Terms and Conditions of Sale only. Zilog, Inc. makes no warranty,
express, statutory, implied or by description, regarding the information
set forth herein or regarding the freedom of the described devices from
intellectual property infringement. Zilog, Inc. makes no warranty of
merchantability or fitness for any purpose. Zilog, Inc. shall not be
responsible for any errors that may appear in this document. Zilog, Inc.
makes no commitment to update or keep current the information
contained in this document.
Zilog’s products are not authorized for use as critical components in life
support devices or systems unless a specific written agreement pertaining
to such intended use is executed between the customer and Zilog prior
to use. Life support devices or systems are those which are intended for
surgical implantation into the body, or which sustains life whose failure
to perform, when properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result in significant
injury to the user.
Zilog, Inc. 210 East Hacienda Ave.
Campbell, CA 95008-6600
Telephone (408) 370-8000
Telex 910-338-7621
FAX 408 370-8056
5