English
Language : 

Z8932111ZEM Datasheet, PDF (4/5 Pages) Zilog, Inc. – Provides Source-Level Debugging for DSP Codes
Z8932111ZEM
DSP Family Emulator Development ToolsÑZ89321
ZiLOG
PRECAUTIONS
1. GUI software versions prior to 3.00 are incompatible
with hardware containing BOOTROM 3.00. The GUI
software may still boot; however, the program could
fail at some later point.
2. When simultaneously running two different GUI ver-
sions on two different Communication Ports, the
former executed version is used for both emulators.
These are typical Windows OS bugs.
3. The emulator cannot be operated while performing
ESD/EMI testing on the target board.
4. The GUI occasionally indicates Executing after a
HALT instruction. Pushing the GO button also indi-
cates Executing (Executing displays in the caption
bar of the Debug window). This condition is applica-
ble to DSPICE GUI software only.
5. Ensure that the target cable is correctly aligned (pin-1
to pin-1) before inserting into the target system. Incor-
rect alignment may damage the emulator and/or the
target system.
6. Do not start the emulator with an OTP device in the
programming socket. This action may cause the emu-
lator to not start up correctly.
7. A shorted PLCC or DIP OTP can crash the emulator
when inserted into the OTP programming socket. If a
PLCC part is inserted in such a way as to cause a tem-
porary short, then functionality is lost. An attempt to
perform BLANK CHECK on such a part causes the
“hour-glass” to run incessantly. The Windows appli-
cation must be reset and restarted.
8. The status color bar in the OTP dialog box clears when
a new window opens on top of it. This condition ap-
plies to DSPICE GUI software only.
9. Do not press the emulator MASTER RESET when the
emulator is in the OTP dialog for programming. If
MASTER RESET is pressed while the GUI is doing
OTP programming, close the OTP dialog box and re-
open it to reload the information back to the hardware.
Note: The emulator is really sitting idle, although the Com-
mand Status shows “Processing” after the GUI reestab-
lishes the communication link when “Retry” was
selected in the “Out of Synchronization with the Emu-
lator” dialog box.
10. When device serialization is enabled in the OTP dia-
log, the GUI copies the current serial number to code
memory immediately before performing a VERIFY
operation. If this behavior is undesirable, then device
serialization should be disabled prior to invoking the
VERIFY operation.
11. Do not use the OTP operation while in the Debug’s
trace and/or animation mode.
12. Option selections for the OTP are not cleared after
changing a Device selection.
13. The Edit|Fill|Memory Decimal radix option will not
accept entry of more than 9,999 for the Fill Value.
Please use the Hexadecimal radix option when using a
fill value of more than 9,999 decimal.
4
DS006700-DSP0299