English
Language : 

AC-162E Datasheet, PDF (17/20 Pages) ZETTLER Electronics – SPECIFICATIONS FOR LCD MODULE
13.6 RELIABILITY
Test Item
Test Conditions
Normal Temp. type
Extended Temp. type
Note
High Temperature Operation
50±3°C , t=96 hrs
70±3°C , t=96 hrs
Low Temperature Operation
0±3°C , t=96 hrs
-20±3°C , t=96 hrs
High Temperature Storage
70±3°C , t=96 hrs
80±3°C , t=96 hrs 1,2
Low Temperature Storage
-20±3°C , t=96 hrs
-30±3°C , t=96 hrs 1,2
Temperature Cycle
-20°C ~ 25°C ~ 70°C -30°C ~ 25°C ~ 80°C
30 m in. 5 min.
( 1 cycle )
30 min. 30 min. 5 min.
( 1 cycle )
30 min. 1,2
Total 5 cycle
Total 5 cycle
Humidity Test
40 °C, Humidity 90%, 96 hrs
1,2
Sweep frequency : 10 ~ 55 ~ 10 Hz/1min
Vibration Test (Packing)
Amplitude : 0.75mm
Test direction : X.Y.Z/3 axis
2
Duration : 30min/each axis
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
(15-35°C , 45-65%RH).
Definitions of life end point :
Current drain should be smaller than the specific value.
Function of the module should be maintained.
Appearance and display quality should not have degraded noticeably.
Contrast ratio should be greater than 50% of the initial value.
Date : 2001/12/12
AMPIRE CO., LTD.
17