9.6 RELIABILITY
Test Item
Test Conditions
Note
High Temperature Operation
70±3°C , t=96 hrs
Low Temperature Operation
-20±3°C , t=96 hrs
High Temperature Storage
80±3°C , t=96 hrs
1,2
Low Temperature Storage
-30±3°C , t=96 hrs
1,2
-30°C ~ 25°C ~ 80°C
Thermal Shock Test
30 min. 5 min. 30 min. ( 1 cycle )
1,2
Total 5 cycle
Sweep frequency 10~55~10 Hz/1min
Vibration Test (Packing)
Amplitude : 0.75mm
Test direction : X.Y.Z/3 axis
2
Duration : 30min/each axis
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
(15-35°C , 45-65%RH).
Definitions of life end point :
z Current drain should be smaller than the specific value.
z Function of the module should be maintained.
z Appearance and display quality should not have degraded noticeably.
z Contrast ratio should be greater than 50% of the initial value.