12.6 RELIABILITY
12.7 RELIABILITY
Test Item
Test Conditions
Note
High Temperature Operation
Low Temperature Operation
High Temperature Storage
Low Temperature Storage
Temperature Cycle
50±3°C , t=96 hrs
0±3°C , t=96 hrs
70±3°C , t=96 hrs
1,2
-20±3°C , t=96 hrs
1,2
-20°C ~ 25°C ~ 70°C
30 m in. 5 min. 30 min. ( 1 cycle ) 1,2
Total 5 cycle
Humidity Test
40 °C, Humidity 90%, 96 hrs
1,2
Sweep frequency : 10 ~ 55 ~ 10 Hz/1min
Vibration Test (Packing)
Amplitude : 0.75mm
Test direction : X.Y.Z/3 axis
2
Duration : 30min/each axis
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
(15-35°C , 45-65%RH).
Definitions of life end point :
Current drain should be smaller than the specific value.
Function of the module should be maintained.
Appearance and display quality should not have degraded noticeably.
Contrast ratio should be greater than 50% of the initial value.
Date : 2001/12/12
AMPIRE CO., LTD.
14