English
Language : 

RUC Datasheet, PDF (1/6 Pages) ZETTLER Electronics – Power relays of general application
RUC
industrial relays of small dimensions
• Power relays of general application • AC and DC coils • Mounting:
in sockets; 35 mm rail mount acc. to PN-EN 60715; on panel; PCB
• Versions: faston 187 (4,8 x 0,5 mm); faston 250 (6,3 x 0,8 mm) • 3 mm con-
tact gap (option - only in versions with normally open contacts) • Additional
features: K - test button; L - light indicator (LED) • Applications: control
of electromagnets; systems of heating, cooling, ventillation, air conditioning;
control with single-phase and three-phase motors; catering industry machines
with adaptor (V) with adaptor (H) and equipment; automation systems; photoelectric systems; etc.
Contact data
• Recognitions, certifications, directives: RoHS,
Number and type of contacts
2 CO, 3 CO, 2 NO, 3 NO
2 NO, 3 NO with contact gap  3 mm
Contact material
Rated / max. switching voltage
AgCdO, AgNi
AC 400 V / 440 V
230 V / 250 V ❶
Min. switching voltage
5 V AgNi, 10 V AgCdO
Rated load
AC1 16 A / 250 V AC or 10 A / 400 V AC 16 A / 250 V AC ❶
DC1 16 A / 24 V DC (see Fig. 3)
Min. switching current
5 mA AgNi, 10 mA AgCdO
Max. inrush current
40 A
Rated current
16 A
Max. breaking capacity
AC1 4 000 VA
Min. breaking capacity
0,3 W AgNi, 1 W AgCdO
Contact resistance
 100 m
Max. operating frequency
• at rated load
AC1 1 200 cykli/h
• no load
12 000 cykli/h
Coil data
Rated voltage
AC 6 ... 240 V 50/60 Hz 6 ... 400 V 50 Hz ❶
DC 6 ... 220 V
Must release voltage
AC:  0,15 Un
DC:  0,1 Un
Operating range of supply voltage
see Tables 1, 2, 3, 4
Rated power consumption
AC 2,8 VA 50 Hz
2,5 VA 60 Hz
DC 1,5 W
1,7 W with contact gap  3 mm
Insulation according to PN-EN 60664-1
Insulation rated voltage
400 V AC
Rated surge voltage
4 000 V 1,2 / 50 µs
Overvoltage category
III
Insulation pollution degree
2
Dielectric strength
• between coil and
2 500 V AC type of insulation: basic
contacts
1 500 V AC type of clearance: micro-disconnection
• contact clearance
2 500 V AC with contact gap  3 mm, type of clearance: full-disconnection
• pole - pole
2 500 V AC type of insulation: basic
Contact - coil distance • clearance
 5 mm 2 CO, 2 NO  4 mm 3 CO, 3 NO
• creepage
 8 mm 2 CO, 2 NO  5 mm 3 CO, 3 NO
General data
Operating / release time (typical values)
20 ms / 15 ms
Electrical life
• resistive AC1
> 105 16 A, 250 V AC > 105 10 A, 400 V AC
• cos
see Fig. 2
Mechanical life (cycles)
> 107
Motor load according to UL 508
2 CO: 0,33 HP 120 V AC, single-phase motor 0,5 HP 240 V AC, single-phase motor
3 CO: 0,33 HP 120 V AC, single-phase motor 0,5 HP 240 V AC, single-phase motor
3 CO: 0,5 HP 240 V AC, three-phase motor
Dimensions (L x W x H)
RUC faston 4,8 x 0,5 ❷
RUC faston 6,3 x 0,8 ❸
Weight
Ambient temperature
• storage
• operating
80 g ❹
85 g ❺
-40...+85 oC
AC: -40...+55 oC 3 CO, 3 NO / 16 A
DC: -40...+55 oC 3 CO, 3 NO / 16 A
(+70 oC 2 CO, 2 NO / 16 A)
(+70 oC 3 CO, 3 NO / 10 A; 2 CO, 2 NO / 16 A)
Cover protection category
IP 00
PN-EN 60529
Shock / vibration resistance
Solder bath temperature
10 g / 5 g
max. 270 oC
10...150 Hz
Soldering time
max. 5 s
The data in bold type pertain to the standard versions of the relays. ❶ For RUC faston 4,8 x 0,5 with GUC11 socket, max. switching voltages
and coil voltages of relays are limited to 250 V AC / DC. ❷ For plug-in sockets version: 36,1 x 38,6 x 45,5 mm. For version: with (V) adaptor:
58,75 x 38,6 x 45,9 mm; with (H) adaptor: 46,8 x 38,6 x 62,45 mm. For version with mounting flange: 66,3 x 38,6 x 36,1 mm. For PCB version:
36,1 x 38,6 x 52,5 mm. ❸ For version: with (V) adaptor: 62,4 x 38,6 x 45,9 mm; with (H) adaptor: 46,8 x 38,6 x 66,1 mm. For version with mounting
flange: 66,3 x 38,6 x 36,1 mm. ❹ Weight of plug-in sockets version and PCB version (RUC faston 4,8 x 0,5). ❺ Weight of version with (V) or (H)
1
adaptor, and version with mounting flange.
Export Sales Department phone +48 68 47 90 832, 951 • e-mail: export@relpol.com.pl
www.relpol.com.pl