Constraints for the YB1900 are maximum
junction temperature TJ(MAX) = 125℃, and
package thermal resistance, θJA = 220℃/W.
The maximum continuous output current for
YB1900 depends on package power
dissipation and the RDS(ON) of MOSFET at
TJ(MAX). Typical conditions are calculated
under normal ambient condition where TA =
25℃ At 85℃, PD(MAX) = 181mW. At TA = 25℃,
PD(MAX) = 454mW.
The maximum current is calculated by the
following equation:
IOUT < (PD(MAX) / RDS(MAX))^(1/2)
For example, if VIN = 5V, RDS(MAX) = 100mΩ
and TA = 25℃, IOUT(MAX) = 2.2A.
Thermal Shutdown is employed to protect
the device damage when over temperature
160℃.
PCB Layout Consideration
To maximize YB1900 performance, some
board layout rules should be followed:
VIN and VOUT should be routed using wider
than normal traces, and GND should be
connected to a ground plane. For best
performance, CIN and COUT should be
placed close to the package pins.