BLOCK DIAGRAM
1
INPUT
11.5 – 16 VDC
2
GND
5
5VDC
REFERENCE
4
PROGRAMMING
INPUT
0 – 5 VDC
6
INVERTER
HV
TRANSFORMER
CONTROL
THERMAL
SHUTDOWN
GAIN
ADJUST
RECTIFIER
CURRENT
MONITOR
FILTER
7
3
CASE GND
VOLTAGE
MONITOR
CB SERIES
9
HV OUTPUT
0 – 10KV
8
HV RETURN
HOW TO ORDER
PART NUMBER SELECTOR:
Model Number:
CB 101 N
Model
Output Voltage (See table)
Polarity Designator (Blank or N)
* Notes:
1. At Maximum Rated Output Voltage.
2. Specifications after 1 hour warm-up, full load, at 25°C unless other wise indicated.
3. Typical Performance.
4. All grounds internally connected, except case. There should not be more than 50 volts potential between the case ground (pin 3) and the circuit ground (pins 2 and 8). Isolated case assists low noise
design efforts. Case pin must be connected to ground for proper operation.
5. Proper thermal management techniques are required to maintain safe case temperature at maximum power output.
6. 20–100%.
7. SET POINT ACCURACY refers to the ability of the unit to accurately deliver the voltage intended by the applied programming. The resultant output voltage will be within +/-1% of that programmed.
LINEARITY refers to how much the transfer function can deviate from a straight line in the absence of any set point error.
GAIN ADJUSTMENT refers to the ability to alter the gain of the circuit to bring the resultant output voltage to the programmed setpoint. This is intended to allow compensation for set point accuracy error.
XP-EMCO reserves the right to make changes on products and literature, including specifications, without notice. XP-EMCO standard product models are not recommended for “copy-exact” applications or any other application restricting product
changes. “Copy-exact” options are available. Please contact an XP-EMCO sales representative for more details.
WWW.XPPOWER.COM
5809J
PAGE 7