English
Language : 

CCL400 Datasheet, PDF (6/8 Pages) XP Power Limited – AC-DC Power Supplies
CCL400 Series
Mechanical Details
CCL400
1.00 (25.4)
0.40 (10.2)
1.57 (39.9)
Input Connector
CON1
1
2
3
Optional Input Connector CON1 (add suffix ‘-S’)
0.40 (10.2)
0.52 (13.3)
3 Way DINKLE DT-2C-B14W-03
M3 SCREWS IN 3 POSTIONS
TORQUE TO 7lbs-in (80 cNm) MAX.
1.00 (25.4)
0.90 (22.9)
AC-DC Power Supplies
7.12 (180.9)
6.60 (167.6)
2x M3 Max depth 0.16 in (4 mm)
6.60 (167.6)
6.10 (154.9)
DETAIL A
SIGNALS CONNECTOR CON4
10 WAY JST B10B-PHDSS
Pin2
Pin1
Pin10
A
Pin9
OUTPUT
VOLTAGE
CONTROL
+VE
-VE
OUTPUT TERMINALS
M4 SCREWS IN 2 POSITIONS.
TORQUE TO
8 lbs-in (90 cNm) MAX.
2x M3 Max depth 0.16 in (4 mm)
3.95 (100.3)
3.20 (81.3)
3x M3 Max depth 0.12 in (3 mm)
0.75 (19.05)
CON1 Input Connector
(Dinkle 166-0P33)
Pin
Function
1
Line
2
Neutral
3
Earth
Output Connector
Pin
Function
1
+V1
2
+ V1 RTN
Notes
1. Dimensions shown in inches (mm).
2. CON4 Mating Plug: JST-PHDR-10VS
Contact: 26-22-AWG (JST-SPHD-001T-P0.5
3. For optional screw terminal input connector, add suffix ‘-S’
to the model number. i.e. CCL400PS12-S (contact sales for
availability).
CON4 Signals Connector
(JST B10B-PHDSS)
Pin
Function
1 + Standby
2 + Standby
3 - Standby
4 - Standby
5 Power Fail (Emitter)
6 Power Fail (Collector)
7 Inhibit (Cathode)
8 Inhibit (Anode)
9 - Sense
10 + Sense
www.xppower.com
6