English
Language : 

MFA350PS12 Datasheet, PDF (4/4 Pages) XP Power Limited – AC-DC Power Supplies
Models and Ratings
Output Voltage V1
12.0 VDC
24.0 VDC
48.0 VDC
Maximum Output Current
29.0 A
14.5 A
7.3 A
Standby Supply V3
5 V/0.3 A
5 V/0.3 A
5 V/0.3 A
Max Power
350 W
350 W
352 W
MFA350-H
Model Number
MFA350PS12-H
MFA350PS24-H
MFA350PS48-H
Mechanical Details
Pin Connections
PIN CONNECTIONS
OUTPUT CONNECTOR
FCI 51732-035-LF
A1
+Sense
A2
Not Used
A3
DC OK
B1
-Sense
B2
Not Used
B3
AC OK
C1
Current Share
C2
Not Used
C3
5 V Standby V3
D1
Not Used
D2
ROF (Inhibit/Enable)
D3 5 V Standby Return V3
P1
-V1
P2
-V1
P3
+V1
P4
+V1
PIN CONNECTIONS
OUTPUT CONNECTOR
123
D
C
B
A
P1 P2 P3 P4
Viewed looking at PSU male part
OUTPUT CONNECTOR
0.125
(3.18)
1.60
(40.6)
GUIDE PIN C/L
0.655
(16.64)
0.385
(9.78)
PIN CONNECTIONS
INPUT CONNECTOR IEC320
Neutral
Live
Earth
Viewed looking at PSU male part
CONNECTOR C/L
3.30
(83.8)
MAX
1.636
(41.55)
IEC320 INPUT CONNECTOR
EJECTOR HANDLE
10.06 (255.52)
10.00 (254.0)
ø0.156 (3.96) EJECTOR PIN
R0.225 (5.71) ROTATION RADIUS
AC INPUT &
DC OUTPUT
HEALTHY LED’S
0.225
(5.72)
0.175
(4.44)
Mating parts: FCI 51762-10401200AA-LF
Notes 1. All dimensions in inches (mm).
Signals MFA350 & MFA350-H
AC OK/Power Fail
DC OK
Remote On/Off (Inhibit/Enable)
POWER SUPPLY
Max 12 V 20 mA
5 V Standby
Pin 9 or C3
330R
AC OK Collector
Pin 1 or B3
POWER SUPPLY
Max 12 V 20 mA
5 V Standby
Pin 9 or C3
330R
DC OK Collector
Pin 4 or A3
See 2nd page of this datasheet
Mechanical Details for location
POWER SUPPLY
Internal
Vref
JP1
AC OK Emitter
Pin 7 or B1
DC OK Emitter
Pin 7 or B1
Pin 2
or D2
J3 Logic Connector
5 V Standby
Return Pin 10
or D3
J3 Logic Connector
5 V Standby
Return Pin 10
or D3
Pin 7 or B1
J3 Logic Connector
Transistor On (<0.8 V): AC NOT OK
Transistor Off (>4.5 V): AC OK
Transistor On (<0.8 V): DC NOT OK
Transistor Off (>4.5 V): DC OK
Thermal Considerations (U Channel)
Jumper (JP1) fitted (standard)
Open or TTL high=PSU On
Short circuit or TTL Low=PSU Off
Jumper (JP1) removed
Open or TTL high=PSU Off
Short circuit or TTL Low=PSU On
Temperature Measurements (Ambient ≤50 ºC)
Component
Max Temperature ºC
T3
90ºC
BR1
105 ºC
D35
85 ºC
L3
90 ºC
C8
105 °C
C63
105 °C
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the
components listed in the table below must not be exceeded. See drawing on 2nd page of this
datasheet for component locations. The temperature should be monitored using K type thermo-
couples placed on the hottest part of the component (out of any direct air flow). See longform
datasheet for further information of service life.
12-Dec-08