MCC Datasheet, PDF (4/9 Pages) XP Power Limited – 400 W Regulated Output
Model Numbering System
MCC 4
Q
Chassis Designations, Power & Sizes
Code
Power
Slots
MCC4
400 W
4
MCC6
400 W + 200 W Aux
4
MCC400/600:
Single (S), Dual (D), Triple (T) or Quad (Q)
(4 slots max where all slots must be filled)
Block Diagram
xppower.com
1
2
3
4
2J 2J 2J 2J E
X
X
X
X
Modules Output Voltage / Current Rating
V
I
W Slots Code
3.3 22.7 A 75 W 1
2C
3.3 45.4 A 150 W 2
3C
3.3 80.0 A 264 W 4
4C (2)
5 20.0 A 100 W 1
2D
5 40.0 A 200 W 2
3D
5 80.0 A 400 W 4
4D (2)
12
8.3 A 100 W 1
2J
12 16.6 A 200 W 2
3J
12 33.3 A 400 W 4
4J (2)
15
6.6 A 100 W 1
2L
15 13.3 A 200 W 2
3L
15 26.7 A 400 W 4
4L (2)
24
4.1 A 100 W 1
2P
24
8.3 A 200 W 2
3P
24 16.7 A 400 W 4
4P (2)
28
3.5 A 100 W 1
2Q
28
7.1 A 200 W 2
3Q
28 14.3 A 400 W 4
4Q (2)
36 2.78 A 100 W 1
2T
36 5.56 A 200 W 2
3T
36 11.11 A 400 W 4
4T
48
2.1 A 100 W 1
2W
48
4.1 A 200 W 2
3W
48
8.3 A 400 W 4
4W (2)
D - DC OK, leave blank if not required
Q - Low noise output
L - Passive filtering only (4)
P - Conformal coating
S - Standard
E- Screening option (3)
A- Auxiliary Turn Off (5)
1. Modules 1 to 4 available for MCC400/600
e.g. MCC4Q2D2J2L2PED.
2. The 4 series output modules to be used with
single MCC400/600 models only.
3. DC-DC output modules are stress-screened
for -55 ˚C to +100 ˚C operation.
4. Low cost option with passive EMI filtering
only. No auxiliary output, EMI to EN55022
level B only.
5. Global inhibit will also turn off the auxiliary
output - Option A.
CN1
Global Enable
and Disable
CN1
Input EMI Filter
Input EMI Filter
Active Surge and Spike
Protection for 400 W
Regulated Ouputs
Internal Holdup
Capacitor
Active Surge and Spike
Protection for 200 W
Output 1
2-48 VDC
Output 2
2-48 VDC
Output 3
2-48 VDC
Output 4
2-48 VDC
O/P 1
O/P 2
O/P 3
O/P 4
CN2
Non-Regulated
200 W Output <36 VDC
CN2
External Holdup
Capacitor
Figure 2. Block Diagram
CN1
Optional DC OK
Signal
4