English
Language : 

JHL0612S05 Datasheet, PDF (3/3 Pages) XP Power Limited – JHL06 Series DC-DC Converter
JHL06 Series
DC-DC Converter
EMC: Emissions
Phenomenon
Conducted
Radiated
EMC: Immunity
Phenomenon
Immunity
ESD Immunity
Radiated Immunity
EFT/Burst
Surges
Conducted Immunity
Magnetic Fields
Safety Approvals
Safety Approvals
Safety Agency
CB Report
UL
EN
Standard
EN55011
EN55011
Test Level
Level A
Level A
Notes & Conditions
Standard
IEC60601-1-2
EN61000-4-2
Test Level
Ed 4.0: 2014
±8 kv Contact, ±15 kv Air
Criteria
As Below
A
Notes & Conditions
EN61000-4-3
10 V/m
A
80 MHz - 2.7 GHz plus discrete communication
proximity field frequencies
EN61000-4-4
2
A
EN61000-4-5
1
A
EN61000-4-6
3 Vm
A
EN61000-4-8
30 A/m
A
ANSI/AMMI ES60601-1 3rd Edition, CSA-22.2 No.60601-1:2008, IEC60601-1 3rd Edition
Safety Standard
IEC60601-1 Including Risk Management
ANSI/AAMI ES60601-1 3rd Ed. & CSA C22.2, No.60601-1:2008
EN60601-1
Notes & Conditions
Medical
Medical
Medical
Application Notes
Derating Curve
100
80
60
1
2
40
3
20
0
-20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature (°C)
External Output Trim
Trim
Trim Up
-Vout
+ Vout
Trim Down
Trim
For 5 V output:
Trim +10%, R = 3.4 k typical
Trim -10%, R = 1.1 k typical
For 12 V output:
Trim +10%, R = 5.9 k typical
Trim -10%, R = 11.3 k typical
For 15 V output:
Trim +10%, R = 8.4 k typical
Trim -10%, R = 10.4 k typical
For ±12 V output:
Trim +10%, R = 12.8 k typical
Trim -10%, R = 9.5 k typical
For ±15 V output:
Trim +10%, R = 18 k typical
Trim -10%, R = 14.8 k typical
3
www.xppower.com