English
Language : 

JCM30 Datasheet, PDF (3/4 Pages) XP Power Limited – DC-DC Converter
JCM30 Series
DC-DC Converter
EMC: Emissions
Phenomenon
Conducted
Radiated
EMC: Immunity
Phenomenon
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Fields
Standard
EN55032
EN55032
Test Level
Class A
Class A
Notes & Conditions
See Application Note
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Test Level
±6 kV/±8 kV
20 Vrms
2 kV
2 kV
10 V rms
100 A/m
Criteria
A
A
A
A
A
A
Notes & Conditions
Contact/Air Discharge
External input filter required, see applications note
External input filter required, see applications note
Mechanical Details
Top View
6
5
4
1.0
(25.4)
3
21
1.0 (25.4)
0.1
(2.54)
0.4
0.4
(10.16) (10.16)
4
6
5
0.1
(2.54)
0.5
(0.02)
0.8
(20.32)
1
0.2
0.1 (5.08)
(2.54)
23
0.3
(7.62)
0.6
(15.24)
DIA
0.04
(1.0)
0.1
(2.54)
0.41
(10.4)
Print
Face
0.24
(6.0)
1.0 (25.4)
0.66 (16.8)
0.04 (1.0)
1.0
(25.4)
Pin Connections
Pin Single
1 +Vin
2
-Vin
Dual
+Vin
-Vin
3
Remote Remote
On/Off On/Off
4 +Vout +Vout
5
Trim Common
6 -Vout -Vout
Notes
1. All dimensions are in inches (mm)
2. Weight: 0.042 lbs (19 g) approx.
3. Pin diameter: 0.04±0.002 (1.0 ±0.05)
4. Pin pitch tolerance: ±0.014 (±0.35)
5. Case tolerance: ±0.02 (±0.5)
3
www.xppower.com