JCK50 Datasheet, PDF (3/4 Pages) XP Power Limited – DC-DC Converter
JCK50 Series
DC-DC Converter
EMC: Immunity
Phenomenon
ESD
Radiated
EFT/Burst
Surge
Conducted
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Test Level
±8 kV air discharge, ±6 kV contact
10 V/m
±2 kV
±1 kV
10 V rms
Criteria
A
A
A
A
A
Notes & Conditions
With external capacitor,
suggested part is CHEMI-CON KY 220 µF/100V
With external capacitor,
suggested part is CHEMI-CON KY 220 µF/100V
Mechanical Details
0.10
(2.54)
0.10
(2.54)
0.40 0.40
(10.16) (10.16)
4
5
6
0.10
(2.54)
0.10
(2.59)
Bottom View
0.10
(2.54)
12
3
5.08
(0.20)
0.60
(15.24)
0.10
(2.54)
0.45
(11.5)
0.02
(0.5)
Dia
0.04
(1.0)
Print
Face
2.0
(50.8)
6.00
(0.24)
Optional Heatsink (-HK)
1.0 (25.4)
Heat Sink
Thermal Pad
Converter
0.69
(17.6)
2.0
Top
(50.8)
Application Notes
Derating Curve
Pin Connections
Pin
Single
1
+Vin
2
-Vin
3
Remote On/Off
4
+Vout
5
-Vout
6
Trim
Notes
1. All dimensions are in inches (mm)
2. Weight: 0.1 lbs (45.0g) approx.
3. Tolerance: X.XX±0.01 (X.X±0.25)
X.XXX±0.005 (X.XX±0.13)
4. Pin Tolerance: ±0.002 (±0.05)
100
without heatsink
with heatsink
75
50
25
-40 -20
0
20 40 50 5660 70 80 85 95 100 120
Ambient Temperature (°C)
3