English
Language : 

ISE0303A Datasheet, PDF (3/3 Pages) XP Power Limited – ISE Series DC-DC Converter
ISE Series
EMC: Emissions
Phenomenon
Conducted
Radiated
EMC: Immunity
Phenomenon
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Fields
Load Regulation
Standard
EN55022
EN55022
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
DC-DC Converter
Test Level
Class B
Class B
Notes & Conditions
See Application Note for Class B filter
See Application Note for Class B filter
Test Level
3
3 V/m
2
2
3 V rms
1 A/m
Criteria
B
A
B
B
A
A
Notes & Conditions
External input capacitor required, 330 µF/100 V
External input capacitor required, 330 µF/100 V
115
105
Typical Load Curve
100
0
50
70
Load (%)
For 3.3 V output models
+2.5%
-2.5%
-7.5%
100
110
105
Typical Load Curve
100
0
50
70
Load (%)
For all other models
+2.5%
-2.5%
-7.5%
100
Application Note
EMI Filter for Class B Emissions
6.8 µH
4.7 µF, 50 V
+ Vin
+ Vout
ISE
-Vin
0V
C
Load
Output Voltage
3.3
5/6
9
12
15
24
C
10.00 µF
10.00 µF
4.70 µF
2.20 µF
1.00 µF
0.47 µF
3
www.xppower.com
18 July 16