English
Language : 

GCS Datasheet, PDF (3/14 Pages) XP Power Limited – AC-DC Power Supplies 150/180/250/350 Watts
GCS Series
AC-DC Power Supplies
Output
Characteristic
Output Voltage - V1
Initial Set Accuracy
Output Voltage Adjustment -V1
Minimum Load
Start Up Delay
Hold Up Time
Drift
Line Regulation
Load Regulation
Transient Response - V1
Over/Undershoot - V1
Ripple & Noise - V1
Overvoltage Protection - V1
Overload Protection - V1
Short Circuit Protection - V1
Temperature Coefficient
Overtemperature Protection
Minimum
12
±2
0
110
110
Typical
20
16/18
25
17
17
0
110
Maximum
56
±1 (V1) & ±5(Vfan)
0.5
±0.2
±0.5
±0.5 (V1) , ±5(Vfan)
4
1
140
150
0.05
Units
VDC
%
%
A
s
ms
%
%
%
%
%
% pk-pk
%
% I nom
%/˚C
°C
Notes & Conditions
See Models and Ratings table
50% load, 115/230 VAC
Via potentiometer. See mech. details, Vfan will track
115/230 VAC full load
GCS150 Models
GCS180 Models
GCS250PS12 (225W)
GCS250 Other Models (250W)
GCS350
After 20 min warm up
90-264 VAC
0-100% load
Recovery within 1% in less than 500 µs
for a 50-75% and 75-50% load step
20 MHz bandwidth, 12V Models 1.5% max
Vnom DC. Output 1, recycle input to reset
See fig. 2. Trip and Restart
Continuous
At measurement point. Present on GCS350 only.
Measured internally, auto resetting
Output Overload Characteristic
Figure 2
GCS180PS12 example (other similar).
12
10
8
6
Trip & Restart
4
2
0
0
2
4
6
8
10
12
14
16
18
20
22
24
Output Load (A)
3
www.xppower.com