English
Language : 

F02 Datasheet, PDF (3/6 Pages) XP Power Limited – ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS
F-SERIES ELECTRICAL SPECIFICATIONS*3
PARAMETER
INPUT VOLTAGE
TURN-ON VOLTAGE
INPUT CURRENT
ISOLATION
INPUT CAPACITANCE
RESPONSE TIME
OUTPUT VOLTAGE TOLERANCE
FREQUENCY
OPERATING TEMPERATURE*5
STORAGE TEMPERATURE
BLOCK DIAGRAM
VALUE
0 TO 12V (F02 TO F20)
0 TO 15V (F30 TO F80)
<0.7V
<500MA, NO LOAD
<1.5A, FULL LOAD
< +/-3.5kV BIAS (F02 TO F60)
< +/-500V BIAS (F70 TO F80)
~240uF
260 ms (typical)
+/-5% (Full Load, 100% output voltage)
25 kHz TO 125 kHz
-10C to +70C (Case)
-25C to +90C
F SERIES
1
(+) In
2
(-) In
Oscillator
Rectifier &
Multiplier
Transformer
3
(+) Output
5
Center tap (for Dual output option)
4
(-) Output
HOT SPOT CASE TEMPERATURE POINT
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
DIMENSIONAL TOLERANCES: .XX = +- 0.03 (0.76), .XXX = +- 0.005 ( 0.127)
WWW.XPPOWER.COM
4722AV03
PAGE 3