English
Language : 

SMH600 Datasheet, PDF (2/6 Pages) YEONHO ELECTRONICS – 6.00mm PITCH CONNECTOR
SMH600
AC-DC Power Supplies
Input
Characteristic
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
Minimum
90
47
T10.0 A/250 V fuse
Typical
6
70
>0.9
<1.0
Maximum
264
63
Units
VAC
Hz
A
A
mA
Notes & Conditions
115 VAC (3.0 A at 230 VAC)
230 VAC (35 A at 115 VAC)
EN61000-3-2 class A
264 VAC
Output
Characteristic
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Drift
Line Regulation
Load Regulation
Over/Undershoot
Transient Response
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection - V1
Remote On/Off
Remote Sense
Minimum
3.3
Typical
Maximum
60
Units
VDC
Notes & Conditions
See Models and Ratings table
±5
%
V1 (V2 of dual output models will track by same % of
adjustment)
±1
1 / 10
2.0
40
10
13
±0.5
±0.5
±1 / ±3 / ±5
1.5
5
%
%
Single / Dual (for regulation)
s
115 VAC
ms
PD1224 model typically 50 ms
ms
115 VAC
%
After 20 min warm up
%
%
Single / Dual V1 / Dual V2 outputs
%
±5
%
Deviation, recovery to within 1% in 500 µs for a 50%
load change
1
% pk-pk
Measured at 20 MHz BW and 10 µF electrolytic
and 0.1 µF ceramic at terminals
130
%
V1 recycle AC input to reset
110
140
%
Trip and restart, auto recovery
Applying short circuit between Remote On/Off pin and signal return turns output off.
Compensates for 0.5 V max. voltage drop on single output models only.
General
Characteristic
Efficiency
Isolation: Input to Output
Input to Ground
Output to Ground
Switching Frequency
Power Density
Signals
Mean Time Between Failure
Weight
Minimum
9.37
115
Typical
90 / 89
60 / 28
3.53 (1.6)
Maximum
3000
1500
250
Units
%
VAC
VAC
VDC
kHz
W/in3
kHrs
lb (kg)
Notes & Conditions
Single output / Dual output at 230 V and full load
PFC / PWM
For U Channel Versions
Power Good
MIL-HDBK-217F at 25 °C GB
End fan ‘-EF’ version
www.xppower.com