JHL03 Datasheet, PDF (2/3 Pages) XP Power Limited – DC-DC Converter
JHL03 Series
DC-DC Converter
Input
Characteristic
Input Voltage Range
Input Current
Inrush Current
Input Filter
Patient Leakage Current
Undervoltage Lockout
Input Surge
Minimum
10
20
Typical
Pi type
On at >8.8 V. Off <8.3 V
On at >17.5 V. Off <17.0 V
Maximum
17
30
25
2
25
50
Units
VDC
VDC
A
µA
VDC
VDC
Notes & Conditions
12 V nominal
24 V nominal
See Models and Ratings table
At 30 VDC input
12 V models
24 V models
12 V models for 3 s
24 V models for 3 s
Output
Characteristic
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Line Regulation
Load Regulation
Cross Regulation
Transient Response
Ripple & Noise
Short Circuit Protection
Overload Protection
Overvoltage Protection
Temperature Coefficient
Minimum
5
0
120
115
Typical
5
2
Maximum
30
±10
±1
±2
±0.3
±1
±4
4
1
200
140
0.03
Units
V
%
%
%
A
ms
ms
%
%
%
% deviation
% pk-pk
%
%
%/ ˚C
Notes & Conditions
See Models and Ratings table
Via external resistors, see Application Notes
on V1
on V2 of dual output models
No minimum load required
0 - 100% load
On dual output models with one output set to 50% load and
the other varied from 10% to 100% load (D05 20% to 100%)
Recovery to within 1% in <500 µs for a 50% load change
at 0.25 A/µs rate
20 MHz bandwidth
Trip & Restart (hiccup mode), auto recovery
Trip & Restart (hiccup mode)
General
Characteristic
Efficiency
Isolation
Patient Leakage Current
Input to Output Capacitance
Switching Frequency
Power Density
Mean Time Between Failure
Weight
Minimum
4000
Typical
80
250
>1
0.04 (20.0)
Maximum
2
20
7.5
Units
%
VAC
µA
pF
kHz
W/in3
MHrs
lb (g)
Notes & Conditions
See Models and Ratings table
For 1 min. Double/reinforced with a working voltage of 250
VAC. Meets 2 x MOPP per 3rd edition of IEC60601-1 5000
VAC for 10 ms in accordance with IEC60664-1
MIL-HDBK-217F, +25 °C GB
Environmental
Characteristic
Operating Temperature
Storage Temperature
Case Temperature
Humidity
Cooling
Shock
Vibration
Minimum
Typical
Maximum
Units
Notes & Conditions
-20
+80
°C
See derating curve
-40
+100
°C
+100
°C
5
90
%RH
Non-condensing
Natural convection
±3 shocks in each plane, total 18 shocks of 30 g : 11 ms halfsine. Conforms to EN60068-2-27 & EN60068-2-47
10-500 Hz at 2 g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
www.xppower.com
2