Input
Characteristic
Input Voltage Range
Input Filter
Input Reflected Ripple
Input Surge
Undervoltage Lockout
Remote On/Off
Minimum
Typical
Maximum
9
36
18
75
Pi type
20
50
100
ON at >4.5 V, OFF at <8 V
ON at >8.5 V, OFF at <17 V
ON: Logic high (2.5 - 50 V) or open circuit
OFF: Logic low (<0.8 V) or short pin 1 to pin 2
Units
VDC
VDC
mA pk-pk
VDC for 1 s
VDC for 1 s
Notes & Conditions
24 V nominal
48 V nominal
Through 12 µH inductor and 47 µF capacitor
24 V models
48 V models
24 V models
48 V models
Output
Characteristic
Output Voltage
Initial Set Accuracy
Output Voltage Balance
Minimum Load
Line Regulation
Load Regulation
Cross Regulation
Transient Response
Ripple & Noise
Overload Protection
Short Circuit Protection
Maximum Capacitive Load
Temperature Coefficient
Minimum
3.3
110
Typical
±1.0
±1.0
±0.5
±0.5
3
150
Maximum
30
±2.0
±1.0
±1.2
±5
100
0.02
Units
VDC
%
%
A
%
%
%
% deviation
mV pk-pk
%
%/ ˚C
Notes & Conditions
See Models and Ratings table
For dual output with balanced laods
See Models and Ratings table
15% to 100% load
On dual output models when one load is varied between
25% and 100% and other is fixed at 100%
Recovery within 1% in less than 600 µs for a 25% load
change.
20 MHz bandwidth. Measured using 0.47 µF ceramic
capacitor.
Foldback
Continuous, with auto recovery
See Models and Ratings table
General
Characteristic
Efficiency
Isolation: Input to Output
Isolation Resistance
Isolation Capacitance
Switching Frequency
Power Density
Mean Time Between Failure
Weight
Moisture Sensitivity Level
Minimum
1500/1800
109
Level 2
Typical
80
1200
330
350
0.017 (7.8)
Maximum
1500
17.2
Units
%
VDC
Ω
pF
kHz
W/in3
kHrs
lb (g)
Notes & Conditions
See Models and Ratings table
60 s/1 s
At 500 VDC
At 1 V, 100 kHz
MIL-HDBK-217F, +25 °C GB
IPC/JEDEC J-STD-020D.1
Environmental
Characteristic
Operating Temperature
Storage Temperature
Case Temperature
Humidity
Cooling
Case Flammability
Lead-Free Reflow Solder Process
Minimum
-40
-50
UL 94V-0 Rated
Typical
Maximum
+100
+125
+105
95
Units
°C
°C
°C
%RH
Notes & Conditions
See Derating Curve.
Non-condensing
Natural convection
Non conductive black plastic
IPC/JEDEC J-STD-020D.1
www.xppower.com