English
Language : 

IMA01 Datasheet, PDF (2/4 Pages) XP Power Limited – DC-DC Converter
IMA01 Series
DC-DC Converter
Input
Characteristic
Input Voltage Range
Input Reflected Ripple Current
Input Surge
Minimum
4.5
10.8
13.5
21.6
Output
Characteristic
Output Voltage
Initial Set Accuracy
Minimum Load
Line Regulation
Load Regulation
Cross Regulation
Ripple & Noise
Short Circuit Protection
Maximum Capacitive Load
Temperature Coefficient
General
Characteristic
Efficiency
Isolation: Input to Output
Patient Leakage Current
Isolation Resistance
Isolation Capacitance
Switching Frequency
Power Density
Mean Time Between Failure
Weight
Environmental
Characteristic
Operating Temperature
Storage Temperature
Case Temperature
Humidity
Cooling
Minimum
3.3
10
Minimum
4000
109
50
2.5
Minimum
-40
-40
2.5
Typical
20
Typical
10
±4
Typical
75
10
0.008 (3.6)
Typical
Maximum
5.5
13.2
16.5
26.4
7
15
18
28
Units
VDC
mA pk-pk
VDC for 100 ms
Notes & Conditions
5 V nominal
12 V nominal
15 V nominal
24 V nominal
Through 12 µH inductor and 47 µF capacitor
5 V models
12 V models
15 V nominal
24 V nominal
Maximum
30
±5
±1.2
150
0.03
Units
VDC
%
%
%/1%
%
%
mV pk-pk
%/ ˚C
Notes & Conditions
See Models and Ratings table
At full load
Minimum load required to meet specified regulation
Output changes by max of 1.2% for each 1% change in
input voltage
From 10% to full load, see application note
On dual output models, when one output is at 25% load
and other is varied from 10% load to full load
20 MHz bandwidth. Measured using 10 µF electrolytic in
parallel with 0.1 µF ceramic capacitor
Continuous
See Models and Ratings table
Maximum
2
20
100
8.2
Units
%
VAC
µA
Ω
pF
kHz
W/in3
MHrs
lb (g)
Notes & Conditions
1 x MOPP at 250 VAC working voltage, 2 x MOPP at
125 VAC working voltage
MIL-HDBK-217F, +25 °C GB
Maximum
+75
+125
+100
95
Units
°C
°C
°C
%RH
Notes & Conditions
No derating
Non-condensing
Natural convection
www.xppower.com