English
Language : 

EML15 Datasheet, PDF (2/4 Pages) XP Power Limited – AC-DC Power Supplies
EML15 Series
AC-DC Power Supplies
Input
Characteristic
Input Voltage Range
Input Frequency
Input Current - Full Load
No Load Input Power
Inrush Current
Earth Leakage Current
Input Protection
Minimum
85
120
47
Typical
0.32/0.16
20/40
Maximum
264
370
63
0.3
F2.0A/250 V internal fuse fitted in line and neutral
Units
VAC
VDC
Hz
A rms
W
A
Notes & Conditions
At 115/230 VAC
At 115/230 VAC
Class II construction no earth
Output
Characteristic
Output Voltage
Initial Set Accuracy
Output Voltage Adjustment
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature Coefficient
Minimum
3
0
12
195
115
120
Typical
Maximum
48
±1
±5
2
14
±0.5
±1
4
50
120
200
216
130
150
0.05
Units
VDC
%
%
A
s
ms
ms
%
%
%
mV pk-pk
mV pk-pk
mV pk-pk
% Vnom
% Vnom
%
%/˚C
Notes & Conditions
See Models and Ratings table
Not encapsulated units
No minimum load required
at full load and 115 VAC
Deviation, recovery within 1% in less than 500 µs
for a 25% load change
3.3-5 V versions, 20 MHz bandwidth
12-15 V versions, 20 MHz bandwidth
24-48 V versions, 20 MHz bandwidth
3.3 V versions, recycle input to reset
All other versions, recycle input to reset
Trip & Restart (hiccup mode)
General
Characteristic
Efficiency
Isolation: Input to Output
Switching Frequency
Power Density
Mean Time Between Failure
Weight
Minimum
75
4000
Typical
80
70
>400
0.07 (35)
0.20 (90)
0.24 (110)
Maximum
82
4.8
Units
%
VAC
kHz
W/in3
kHrs
lb (g)
lb (g
lb (g
Notes & Conditions
See Models & Ratings table
PCB Mount version
MIL-HDBK-217F, +25 °C GB
Open frame versions
Encapsulated version
Screw terminal version
Environmental
Characteristic
Operating Temperature
Storage Temperature
Cooling
Humidity
Operating Altitude
Shock
Vibration
Minimum
-20
-40
Typical
Maximum
+70
+85
Units
°C
°C
95
%RH
3048
m
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes
IEC68-2-6, 2 g, 10 Hz to 500 kHz, 10 mins/cycle, 60 mins each cycle
Notes & Conditions
Derate linearly from 100% at +50 °C to 50% at +70 °C
Convection-cooled
Non-condensing
www.xppower.com
2