English
Language : 

MTC35 Datasheet, PDF (17/35 Pages) XP Power Limited – COTS Component for Defense & Avionics Applications
xppower.com
General Specifications
Characteristic
Minimum
Typical
Maximum
Units
Efficiency
84
1500
Isolation Voltage
1000
1000
Switching Frequency
450
Frequency Synchronization
450
550
MTBF
Remote On/Off
Rth Case - Ambient
On = >3.5 V or open circuit; Off = <1.8 V
7.12
Note: Control signal TTL 0-5 VDC square wave. The trigger is the falling edge.
%
VDC
kHz
kHz
˚C/W
MTBF
Model
MTC15028S3V3
MTC15028S05
MTC15028S12
MTC15028S15
MTC15028S28
MTC15028D12
MTC15028D15
25 ˚C GF
1,078,632
1,162,633
1,316,925
1,322,349
1,367,231
1,498,551
1,442,550
40 ˚C GF
158,847
172,796
196,186
199,100
209,016
264,559
258,790
Note: 20 °C and 40 °C are assumed to be baseplate temperatures
Notes & Conditions
See models table and performance graphs
(fig. 28-34)
Input to output
Input to case
Output to case
Fixed
See note.
>1 MHrs to MIL-HDBK-217F at 25 ˚C, GF
See table below
Environmental
Characteristic
Operating Temperature
Storage Temperature
Humidity
Salt Atmosphere
Altitude
Shock
Vibration
Bump
Minimum
-55
-60
Typical
15
Maximum
100
125
95
48
70000
75
2000
40
Units
˚C
˚C
%
Hrs
Ft
g
Hz
g
Notes & Conditions
Baseplate temperature. Start up is at -55 ˚C.
Full specification achievable at -40 ˚C
Relative humidity,
MIL-STD-810F Method 507.4
MIL-STD 810F Method 509.4
MIL-STD 810F Method 500.4
MIL-STD 810F Method 516.5
MIL-STD 810F Method 514.5,
table 514.5-VIII
2000 bumps in each axis
MIL-STD 810F Method 516.5
Electromagnetic Compatibility
EMC
Conducted Emissions
Standard
MIL-STD-461E/F
DEF-STAN 59-411
EN55022
Immunity
MIL-STD-1275A-D
MIL-STD-704B-F
Conducted Susceptibility
MIL-STD-461E/F
DEF-STAN 62-5 part 6 iss.5
Note: 0.5 Ω source impedance
Test Level
CE102
DCE01/DCE02
Class B
Spikes
Surge
Ripple
CS101, CS114,
CS115, CS116
Criteria
±250 V for 100 µs
100 V for 50 ms (see note)
14 VAC pk-pk
50 V for 10 ms
Notes & Conditions
When used in conjuction with
standard EMI filter, DSF and FSO
series
When used in conjuction with
standard surge protection module,
DSF and FSO series
When used in conjuction with
standard surge protection module,
DSF and FSO series
3