WT200 Datasheet, PDF (1/2 Pages) XP Power Limited – DC-DC Power Supplies | |||
|
5 Watts
WT Series
xppower.com
⢠2:1 Input Range
⢠Optional 4:1 Input Range
⢠Isolated Outputs
⢠Efficiency to 82%
⢠Fully Regulated Outputs
⢠Optional 3 kVDC Isolation
⢠UL Approved Versions
Specification
Input
Input Voltage Range
⢠12 V (9-18 or 9-36 VDC - A version)
24 V (18-36 or 18-72 VDC - A version)
48 V (36-72 VDC)
Input Current (no load) ⢠See table
Input Filter
⢠Pi network
Undervoltage Lockout ⢠Turn On > 65% nominal input
Turn Off < 63% nominal input
Output
Output Voltage
⢠see tables
Output Voltage Balance ⢠±1% max, dual output models
Initial Set Accuracy ⢠±2% max
Start Up Rise Time
⢠3 ms max
Line Regulation
⢠±0.5% max from high line to low line
Load Regulation
⢠±0.5% max for 10-100% load change for
single output models,
±1.0% max for 25-100% load change for
dual output models
Cross Regulation
⢠±2.2% on dual output models
Transient Response
⢠<1.0% max deviation, recovering within
200 µs for a 50% load change
Ripple & Noise
⢠100 or 1.0% pk-pk, whichever is greater,
20MHz BW
Short Circuit Protection ⢠Continuous with auto recovery
Temperature
Coefficient
⢠±0.05 /°C max
General
Efficiency
Isolation
Switching Frequency
MTBF
⢠See table
⢠500 VDC Input to Output (1000 Mâ¦/80 pF)
Optional high isolation version,
3000 VDC Input to Output, add suffix âXâ
⢠100 kHz typical
⢠1,000 kHrs to MIL-HDBK-217F
Environmental
Operating Temperature ⢠-25 ºC to +70 ºC (see derating curve)
Case Temperature
⢠+95 ºC max
Storage Temperature ⢠-40 ºC to +100 ºC
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
Conducted Immunity
Safety
⢠EN55022, level A conducted
EN55022, level A radiated
⢠EN61000-4-2, level 2
Perf Criteria A
⢠EN61000-4-3 3 V/m
Perf Criteria A
⢠EN61000-4-6 3 V rms
Perf Criteria A
⢠UL1950 (for XU versions only)
|
▷ |