VFT80US05 Datasheet, PDF (1/2 Pages) XP Power Limited – Low Cost, Single Outputs from 5 V to 24 V, Peak Load Capability | |||
|
80 Watts
VFT Series
xppower.com
BRAND
⢠Low Cost
⢠Single Outputs from 5 V to 24 V
⢠Peak Load Capability
⢠High Efficiency
⢠<0.5 W No Load Input Power
⢠2â x 4â Package
⢠Fits 1U Applications
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
No Load Input Power
Input Protection
⢠85-264 VAC
⢠47-63 Hz
⢠2 A max at 115 VAC, 1 A max at
230 VAC
⢠85 A max at 230 VAC, cold start 25 °C
⢠500 µA max at 264 VAC / 60 Hz
⢠EN61000-3-2, class A
⢠<0.5 W max
⢠Internal T3.15A/250 V fuse in line
Output
Output Voltage
⢠See table
Output Voltage Trim ⢠None
Initial Set Accuracy ⢠±2% at 50% load
Minimum Load
⢠No minimum load requirement
Start Up Delay
⢠2 s max
Start Up Rise Time
⢠8 ms typical
Hold Up Time
⢠8 ms typical at full load and 115 VAC
Line Regulation
⢠±0.5% max
Load Regulation
⢠±1.0% max (see note 1)
Transient Response
⢠4% maximum deviation, recovering to less
than 1% within 500 µs for 50% step load
Ripple & Noise
⢠1% max pk-pk (see note 2)
Overvoltage Protection ⢠See table
Overload Protection ⢠110-180%
Short Circuit Protection ⢠Trip and restart (hiccup mode)
Temperature
Coefficient
⢠0.02%/°C
Remote Sense
⢠Fitted to 5 V version compensates for
0.5 V total voltage drop
General
Efficiency
Isolation
Switching Frequency
MTBF
⢠See table
⢠3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
⢠60 kHz ± 10 kHz
⢠>320 kHrs to Bell Core iss. 6
Environmental
Operating Temperature ⢠-10 °C to +70 °C derate from 100% load
at 50 °C to 50% load at 70 °C
Cooling
⢠VFT80US05: convection-cooled 40 W,
forced-cooled 60 W with 10 CFM
VFT80US12-24: convection-cooled 60 W,
forced-cooled 80 W with 10 CFM
Operating Humidity ⢠5% to 90% RH, non condensing
Operating Altitude
⢠2000 m
Storage Temperature ⢠-40 °C to +85 °C
Shock
⢠IEC68-2-6, 30 g, 11 mins half sine, 3 times
in each of 6 axes
Vibration
⢠IEC68-2-27, 10-500Hz, 2 g 10 mins /
sweep. 60 mins for each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55022, level B conducted & radiated
⢠EN61000-3-2 class A
⢠EN61000-3-3
⢠EN61000-4-2, ±8 kV air, ±4 kV contact,
Perf Criteria A
⢠EN61000-4-3, 3 V/m, Perf Criteria A
⢠EN61000-4-4, level 2, Perf Criteria A
⢠EN61000-4-5, installation class 3,
Perf Criteria A
⢠EN61000-4-6, 3 V, Perf Criteria A
⢠EN61000-4-11, 30% 10 ms,
60%, 100 ms, 100%, 5000 ms
Perf Criteria A, B, B
⢠UL60950-1, IEC60950-1, EN60950-1
|
▷ |