VFT150 Datasheet, PDF (1/2 Pages) XP Power Limited – 150 Watts VFT Series
150 Watts
VFT Series
xppower.com
• 100 W Convection Rating
• 150 W Forced cooled Rating
• 3” x 5” Package
• Single Outputs from 5 V to 48 V
• Built in Fan Supply
• <0.5 W No Load Input Power
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
No Load Input Power
Input Protection
• 90-264 VAC
• 47-63 Hz
• 2.5 A max at 115 VAC, 1.5 A max at
230 VAC
• 80 A max at 230 VAC, cold start 25 °C
• 180 µA max at 230 VAC/50 Hz
• >0.9 at 230 VAC and full load
• <0.5 W
• Internal T3.15 A/250 V fuse in line
Output
Output Voltage
• See table
Output Voltage Trim • None
Initial Set Accuracy • ±2% at 50 % load
Minimum Load
• No minimum load requirement
Start Up Delay
• 2 s max
Start Up Rise Time
• 35 ms typical
Hold Up Time
• 8 ms minimum at full load and 115 VAC
Line Regulation
• ±0.5% max
Load Regulation
• ±0.5% max
Transient Response
• 5% maximum deviation, recovering to less
than 1% within 500 µs for 50% step load
Ripple & Noise
• 5 V version: 85 mV pk-pk max,
1% pk-pk max for others (see note 1)
Overvoltage Protection • 110-135%, recycle input to reset
Overload Protection • 130-160%
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature
Coefficient
• 0.02 %/°C
Remote Sense
• Compensates for 0.5 V total voltage drop
Fan Supply
• 5 V version: 5 V at 200 mA
Other versions: 12 V at 300 mA
General
Efficiency
Isolation
Switching Frequency
MTBF
• Up to 92%, see table
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
• PFC: 45-80 kHz, PWM: 100-115 kHz
• >300 kHrs to MIL HDBK 217F at
25 °C, GB
Environmental
Operating Temperature • -10 °C to +70 °C derate from 100% load
at 50 °C to 50% load at 70 °C for 12, 24 &
48 V versions or 65 °C for 5 & 15 V versions
Cooling
• Convection-cooled: 100 W
Forced-cooled: 150 W
(120 W for 5 V models) with 15 CFM
Operating Humidity • 5% to 90% RH, non condensing
Operating Altitude
• 3000 m
Storage Temperature • -20 °C to +85 °C
Shock
• IEC68-2-6, 30 g, 11 mins half sine, 3 times
in each of 6 axes
Vibration
• IEC68-2-27, 10-55 Hz, 2 g 10 mins /
sweep. 60 mins for each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022, level B conducted & radiated
• EN61000-3-2 class A
EN61000-3-2 class C for loads ≥60 W
• EN61000-3-3
• EN61000-4-2, ±8 kV air, ±4 kV contact,
Perf Criteria A
• EN61000-4-3, 3 V/m, Perf Criteria A
• EN61000-4-4, level 3, Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria A
• EN61000-4-6, 3 V, Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60%, 100 ms, 100%, 5000 ms
Perf Criteria A, B, B
• UL60950-1, IEC60950-1, EN60950-1