VER18 Series
AC-DC Power Supplies
18 Watt
xxx Series • Energy Efficiency Level VI
• European CoC Tier 2
• Interchangeable Mains Connectors Included
• Universal Input
• Output Voltages from 9 V to 24 V
• Class II Construction
• Low Cost
BRAND
The VER18 series of wall plug adaptors comply with the very latest energy efficiency VI standards
with high active mode efficiency and extremely low no load power consumption. Available with a
standard jack plug connector these adaptors suit a wide variety of cost sensitive applications while
maintaining industry leading performance.
Dimensions:
VER (body only):
3.54 x 1.69 x 1.68” (90.5 x 42.0 x 42.7 mm)
Models & Ratings
Output Power
Output Voltage
Output Current
9.0 V
12.0 V
2000 mA
1500 mA
18 W
15.0 V
18.0 V
1250 mA
1000 mA
24.0 V
750 mA
Notes
1. Other output voltages available, contact sales for details.
Total Regulation(2)
5%
5%
5%
5%
5%
Output Connector
5.5 x 2.1 x 12 mm DC Jack
5.5 x 2.1 x 12 mm DC Jack
5.5 x 2.1 x 12 mm DC Jack
5.5 x 2.1 x 12 mm DC Jack
5.5 x 2.1 x 12 mm DC Jack
Model Number
VER18US090-JA
VER18US120-JA
VER18US150-JA
VER18US180-JA
VER18US240-JA
2. Total regulation includes initial set accuracy, line and load regulation.
Input
Characteristic
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Input Protection
Minimum
90
47
Typical
Internal T1.0A/250 VAC fuse
Maximum
264
63
0.23
60
75
Units
VAC
Hz
A
A
mW
Notes & Conditions
100 VAC
240 VAC, cold start at 25 °C
EN61000-3-2, class A
Output
Characteristic
Output Voltage
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Total Regulation
Transient Response
Ripple & Noise
Short Circuit Protection
Temperature Coefficient
1
Minimum
9
0
10
Typical
30
Maximum
24
4
5
4
150
0.05
Units
V
A
s
ms
ms
%
% deviation
mV pk-pk
%/ ˚C
Notes & Conditions
See Models and Ratings table
No minimum load required
Full load and 100 VAC
See Models and Ratings table
Recovery within <1% within 500 µs for a 60% step load
change at 0.15 A/µs
Measured with 20 MHz bandwidth and 47 µF electrolytic in
parallel with 0.1 µF ceramic capacitor
Continuous, trip and restart (hiccup mode) with auto recovery
www.xppower.com