English
Language : 

VER05 Datasheet, PDF (1/5 Pages) XP Power Limited – AC-DC Power Supplies
VER05 Series
AC-DC Power Supplies
5 Watt
xxx Series • Energy Efficiency Level VI
• Barrel Jack & USB Versions
• Interchangeable Mains Connectors Included
• Universal Input
• Output Voltages from 5.0 V to 12.0 V
• Class II Construction
• Low Cost
BRAND
The VER05 series of wall plug adaptors comply with the very latest energy efficiency VI standards
with high active mode efficiency and extremely low no load power consumption. Available with
multiple USB options in addition to the standard jack plug connector these adaptors suit a wide
variety of cost sensitive applications while maintaining industry leading performance.
Dimensions:
VER (body only):
1.45 x 2.16 x 1.69”(37.0 x 55.1x 42.9 mm)
Models & Ratings
Output Power
Output Voltage Output Current Total Regulation(2)
Efficiency
Output Connector
Model Number
5.0 V
1000 mA
5%
77%
USB A in case
VER05US050-BB
5.0 V
1000 mA
5%
74%
Mini USB B
VER05US050-MB
5.0 V
1000 mA
5%
74%
Micro USB B
VER05US050-UB
5W
5.0 V
1000 mA
5%
75%
5.5 x 2.1 x 12 mm DC Jack
VER05US050-JA
6.0 V
830 mA
5%
78%
5.5 x 2.1 x 12 mm DC Jack
VER05US060-JA
9.0 V
550 mA
5%
78%
5.5 x 2.1 x 12 mm DC Jack
VER05US090-JA
12.0 V
420 mA
5%
79%
5.5 x 2.1 x 12 mm DC Jack
VER05US120-JA
Notes
1. Other output voltages available, contact sales for details.
2. Total regulation includes initial set accuracy, line and load regulation.
3. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load
and 115 VAC input.
Input
Characteristic
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Input Protection
Minimum
90
47
Typical
Internal T1.0A/250 VAC fuse
Maximum
264
63
0.25
60
<0.1
Units
VAC
Hz
A
A
W
Notes & Conditions
100 VAC
240 VAC, cold start at 25 °C
EN61000-3-2, class A
Output
Characteristic
Output Voltage
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Total Regulation
Transient Response
Ripple & Noise
Short Circuit Protection
Temperature Coefficient
Minimum
5.0
0
Typical
50
8
Maximum
12.0
4
5
4
200
0.05
Units
V
A
s
ms
ms
%
% deviation
mV pk-pk
%/ ˚C
Notes & Conditions
See Models and Ratings table
No minimum load required
Full load and 100 VAC
See Models and Ratings table
Recovery within <1% within 500 µs for a 50% step load
change at 0.2 A/µs
20 MHz bandwidth
Continuous, trip and restart (hiccup mode) with auto recovery
1
www.xppower.com