Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
⢠8 & 15W: 80-264 VAC
24 W: 80-264 VAC, derate output power
25% <90 VAC
36 W: 90-264 VAC
⢠47-63 Hz
⢠8 W: 0.3 A max at 90 VAC
15 W: 0.5 A max at 90 VAC
24 W: 0.6 A max at 90 VAC
36 W: 0.9 A max at 90 VAC
⢠70 A max at 230 VAC, cold start at 25 °C
⢠EN61000-3-2, class A
⢠<0.3 W
Output
Output Voltage
⢠See tables
Initial Set Accuracy ⢠±5% at 50% load
Minimum Load
⢠No minimum load required
Start Up Delay
⢠2 s typical
Start Up Rise Time
⢠8 & 15 W: 100 ms typical,
24 & 36 W: 50 ms typical
Hold Up Time
⢠5 ms typical at full load and 115 VAC
Line Regulation
⢠±0.5% max
Load Regulation
⢠±5% max
Transient Response
⢠4% max. deviation, recovery to <1%
within 500 µs for a 50% step load change
at 0.2 A/µs
Ripple & Noise
⢠See tables
Overvoltage Protection ⢠See tables
Overload Protection ⢠120-280%
Short Circuit Protection ⢠Trip and restart (hiccup mode)
Temperature
Coefficient
⢠0.2 %/ËC
General
Efficiency
Energy Efficiency
Isolation
Switching Frequency
MTBF
⢠See tables
⢠Level V
Level IV (24 W versions)
⢠8 - 24 W: 4000 VAC Input to Output,
36 W: 3000 VAC Input to Output
⢠8 & 15 W: 132 kHz typical,
24 & 36 W: 65 kHz typical
⢠8 - 24 W: 250 kHrs, 36 W: 200 kHrs
to MIL-HDBK-217F at 25°C, GB
Environmental
Operating Temperature ⢠0 ËC to +40 ËC
Cooling
⢠Natural convection
Operating Humidity ⢠5-95% RH, non-condensing
Storage Temperature ⢠-25 ËC to +70 ËC
Shock
⢠Able to survive 1 m drop onto concrete on
each of 6 axes
Vibration
⢠10-300 Hz, 1 g 15 mins/sweep. 30 mins for
each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022, class B conducted & radiated
⢠EN61000-3-2, class A
⢠EN61000-3-3
⢠EN61000-4-2, ±4 kV contact, ±8 kV air,
Perf Criteria A
⢠EN61000-4-3, 3 V/m, Perf Criteria A
⢠EN61000-4-4, level 2, Perf Criteria A
⢠EN61000-4-5, installation class 3,
Perf Criteria A
⢠EN61000-4-6, 3 V, Perf Criteria A
⢠EN61000-4-8, 1 A/m, Perf Criteria A
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
⢠8 & 15 W: EN60950-1, cUL60950-1,
IEC60950-1, EN60601-1, cUL60601-1,
IEC60601-1;
24 W: EN60950-1, cCSAus60950-1,
IEC60950-1, CSA60950-01-03,
cCSAus60601-1, IEC60601-1, CSA C22.2
No601.1,
36 W: IEC60950-1, EN60950-1, UL60950-1
|
▷ |