VEH90PS12 Datasheet, PDF (1/2 Pages) XP Power Limited – Energy Efficiency Level V, CEC 2008 & EISA 2007 Compliant | |||
|
90 Watts
VEH Series
xppower.com
BRAND
⢠Energy Efficiency Level V
⢠CEC 2008 & EISA 2007 Compliant
⢠High Power Density
⢠Single Outputs from 12 V to 24 V
⢠No Load Input Power <0.5 W
⢠Optional Output Connector
⢠Low Cost
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
No Load Input Power
Input Protection
⢠90-264 VAC
⢠47-63 Hz
⢠1.5 A max at 90 VAC
⢠110 A max at 230 VAC, cold start at 25 °C
⢠<1 mA at 230 VAC/50 Hz
⢠>0.95 at 230 VAC and full load
⢠<0.5 W
⢠Internal T2.0A/250 V fuse in line
General
Efficiency
Energy Efficiency
Isolation
Switching Frequency
MTBF
⢠See table
⢠Level V
⢠3000 VAC Input to Output,
1500 VAC Input to Ground
PS12: 500 VDC Output to Ground,
PS19/24: Negative output is connected to
Ground
⢠PFC: 25-125 kHz, PWM: 60 kHz typical
⢠>160 kHrs to Bell Core iss. 6
Output
Output Voltage
⢠See table
Initial Set Accuracy ⢠±5% at 50% load
Minimum Load
⢠No minimum load requirement
Hold Up Time
⢠10 ms min at 115 VAC, full load
Start Up Delay
⢠3 s max
Start Up Rise Time
⢠8 ms typical
Transient Response
⢠4% maxiumum deviation, recovering to
less than 1% within 500 µs for a 50%
step load change
Line Regulation
⢠±0.5% max
Load Regulation
⢠±5% max
Ripple & Noise
⢠1% pk-pk max, 20 MHz bandwidth
(see note 1)
Overvoltage Protection ⢠See table
Overload Protection ⢠120 -180%
Short Circuit Protection ⢠Continuous (hiccup/trip & restart mode
with auto recovery)
Temperature
Coefficient
⢠±0.04%/°C
Environmental
Operating Temperature ⢠0 °C to +60 °C derate linearly from 100%
load at +40 °C to 50% load at +60 °C,
Storage Temperature ⢠-10 ËC to +85 °C
Operating Humidity ⢠5% to 90% RH non-condensing
Storage Humidity
⢠5% to 95% RH non-condensing
Shock
⢠6 Random drops from 0.7 m with no
damage, 50 g for 20 ms in each of 3 axes
Vibration
⢠2 g variable frequency from 20 Hz to 30 Hz
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022, level B conducted & radiated
⢠EN61000-3-2 class A,
EN61000-3-2 class C >60% load
⢠EN61000-3-3
⢠EN61000-4-2, level 3 Perf Criteria A
⢠EN61000-4-3, 3 V/m Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
⢠EN61000-4-5, installation class 3,
Perf Criteria A
⢠EN61000-4-6, level 2 Perf Criteria A
⢠EN61000-4-8, 3 A/m Perf Criteria A
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
⢠EN60950-1:2001, UL/cUL60950-1
|
▷ |