VEH60US12 Datasheet, PDF (1/2 Pages) XP Power Limited – Energy Efficiency Level V, ≥15 V, CEC 2008 & EISA 2007 Compliant
60 Watts
VEH Series
xppower.com
BRAND
• Energy Efficiency Level V, ≥15 V
• CEC 2008 & EISA 2007 Compliant
• China Compulsory Certfication (CCC) Qualified
• Single Outputs from 12 V to 30 V
• Optional Inlet Connectors
• No Load Input Power <0.5 W
• High Power Density
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
No Load Input Power
Input Protection
• 90-264 VAC
• 47-63 Hz
• 1.7 A max
• 50 A max at 230 VAC, cold start at 25 °C
• <1 mA at 240 VAC/50 Hz
• EN61000-3-2, class A
• <0.5 W
• Internal T3.15A/250 V fuse in line
Output
Output Voltage
• See table
Initial Set Accuracy • ±5% at 50% load
Minimum Load
• No minimum load requirement
Hold Up Time
• 8 ms min at 115 VAC, full load
Start Up Delay
• 3 s max
Start Up Rise Time
• 8 ms typical
Transient Response
• 4% maxiumum deviation, recovering to
less than 1% within 500 µs for a 50%
step load change
Line Regulation
• ±0.5% max
Load Regulation
• ±5% max
Ripple & Noise
• 200 mv pk-pk max, 20 MHz bandwidth
(see note 1)
Overvoltage Protection • See table
Overload Protection • 110 -180%
Short Circuit Protection • Continuous (hiccup/trip & restart mode
with auto recovery)
Temperature
Coefficient
• ±0.04%/˚C
General
Efficiency
Energy Efficiency
Isolation
Switching Frequency
MTBF
• See table
• Level V ≥15 V
• 3000 VAC Input to Output,
1500 VAC Input to Ground.
• 60 kHz ±10 kHz
• >700 kHrs to Bell Core iss. 6
Environmental
Operating Temperature • 0 ˚C to +60 ˚C derate linearly from 100%
load at +40 ˚C to 50% load at +60 ˚C
Storage Temperature • -20 ˚C to +85 ˚C
Operating Humidity • 5% to 90% RH non-condensing
Storage Humidity
• 5% to 95% RH non-condensing
Shock
• 6 random drops from 0.7 m with no
damage, 50 g for 20 ms in each of 3 axes
Vibration
• 2 g variable frequency from 20 Hz to 30 Hz
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022, level B conducted & radiated
• EN61000-3-2 class A
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria B
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-8, 3 A/m Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
• IEC60950-1, EN60950-1, UL/cUL60950-1,
China Compulsory Certification (CCC)
qualified, Approved as Limited Power
Source