VEH20US05 Datasheet, PDF (1/2 Pages) XP Power Limited – Energy Efficiency Level V | |||
|
20/40 Watts
VEH Series
xppower.com
BRAND
⢠Energy Efficiency Level V
⢠CEC 2008 and EISA 2007 Compliant
⢠Optional Inlet Connectors
⢠Class II Versions
⢠+60 °C Operating Temperature
⢠Compact Dimensions
⢠Low Cost
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
Input Protection
No Load Input Power
⢠90-264 VAC
⢠47-63 Hz
⢠0.5 A max VEH20
1.0 A max VEH40
⢠45 A/90 A for 115 VAC/230 VAC,
cold start at 25 °C
⢠0.75 mA at 240 VAC/50 Hz
⢠EN61000-3-2, Class A
⢠Internal fuse fitted in line
VEH20: T1 A, 250 V
VEH40: T3.15 A, 250 V
⢠<0.3 W
Output
Output Voltage
⢠See table
Minimum Load
⢠No minimum load required
Hold Up Time
⢠VEH20: 5 ms min, VEH40: 12 ms min,
at full load & 110 VAC
Start Up Delay
⢠2 s max at full load 100 VAC
Transient Response
⢠2% deviation, recovery to within 1% of
nominal in 500 µs for 50% load change
Regulation
⢠See table
Ripple & Noise
⢠1% pk-pk max, 20 MHz bandwidth
Overvoltage Protection ⢠Not fitted
Overload Protection ⢠110-150%
Short Circuit Protection ⢠Trip & restart (hiccup mode), auto recovery
Temperature
Coefficient
⢠±0.04%/°C
General
Efficiency
Energy Efficiency
Isolation
Switching Frequency
MTBF
⢠87% typical (average of measured values
with output loads of 25%, 50%, 75%
and 100%)
⢠Level V
⢠3000 VAC Input to Output
1500 VAC Input to Ground*
500 VDC Output to Ground*
*Not C2 version
⢠VEH20: 63 kHz typical
VEH40: 20 kHz - 60 kHz variable
⢠>250 kHrs to MIL-HDBK-217F at 25 °C,GB
Environmental
Operating Temperature ⢠0 °C to +60 °C, derate from 100% power
at +40 °C to 50% power at +60 °C
Storage Temperature ⢠-40 °C to +85 °C
Cooling
⢠Convection-cooled
Operating Humidity ⢠5-95% RH, non-condensing
Operating Altitude
⢠2000 m
Shock
⢠10 g, 10 ms on 3 axes
EMC & Safety
Emissions
Harmonic Current
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022 level B conducted & radiated
⢠EN61000-3-2 class A
⢠EN61000-3-3
⢠EN61000-4-2 level 3 Perf criteria A
⢠EN61000-4-3 3 V/m Perf criteria A
⢠EN61000-4-4 level 2 Perf criteria A
⢠EN61000-4-5 installation class 3
Perf criteria A
⢠EN61000-4-6 level 2 Perf criteria A
⢠EN61000-4-8 1 A/m Perf criteria A
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
⢠EN60950-1, UL/cUL60950-1,
Approved as Limited Power Source
|
▷ |