English
Language : 

VEH20 Datasheet, PDF (1/4 Pages) XP Power Limited – AC-DC Power Supplies
VEH20/40-L6 Series
20/40 Watt
xxx Series • Energy Efficiency Level VI
• Optional Inlet Connectors
• Class II Versions
• +60 °C Operating Temperature
• Compact Dimensions
• Low Cost
AC-DC Power Supplies
BRAND
Dimensions:
VEH20: 4.11 x 1.65 x 1.22” (104.0 x 42.0 x 31.0 mm)
VEH40: 4.21 x 1.85 x 1.19” (107.0 x 47.0 x 30.1 mm)
Models & Ratings
Max Output Power
20 W
20 W
20 W
20 W
20 W
40 W
40 W
40 W
40 W
40 W
Output Voltage(1)
12.0 VDC
15.0 VDC
18.0 VDC
24.0 VDC
48.0 VDC
12.0 VDC
15.0 VDC
18.0 VDC
24.0 VDC
48.0 VDC
Output Current
1.67 A
1.33 A
1.11 A
0.83 A
0.42 A
3.33 A
2.67 A
2.22 A
1.67 A
0.83 A
Efficiency(6)
87%
87%
87%
87%
91%
88%
88%
88%
88%
89%
Total Regulation(2)
5%
5%
5%
5%
5%
5%
5%
5%
5%
5%
Model Number
VEH20US12-L6(3,4)
VEH20US15-L6(3,4)
VEH20US18-L6(3,4)
VEH20US24-L6(3,4)
VEH20US48-L6(3,4)
VEH40US12-L6(5)
VEH40US15-L6(5)
VEH40US18-L6(5)
VEH40US24-L6(5)
VEH40US48-L6(5)
Notes
1. Other output voltages available, contact sales for details
2. Total regulation includes line regulation and load regulation.
3. Standard input connector is IEC320-C14 inlet. For optional IEC320-C6 inlet add
suffix ‘C6’ to model number, e.g. VEH20US12-L6C6.
4. For optional class II version with IEC320-C8 inlet add suffix ’C2’ to model number
e.g. VEH20US12-L6C2
5. VEH40USXX-L6 available with output negative connected to ground,
add suffix -G.
6. Minimum average of efficiencies measured at 25%, 50%, 75% and 100% load.
Input
Characteristic
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Input Protection
Minimum
Typical
Maximum
Units
Notes & Conditions
90
264
VAC
47
63
Hz
0.5
1.0
A
100 VAC, VEH20
100 VAC, VEH40
45
90
A
115 VAC, cold start at 25 °C
230 VAC, cold start at 25 °C
EN61000-3-2, class A
0.1
W
VEH20: Internal fuse fitted in line T1.0A/250 VAC, VEH40: Internal fuse fitted in line T3.15 A/250 VAC
1