VEH150 Datasheet, PDF (1/2 Pages) XP Power Limited – 150 Watts VEH Series | |||
|
150 Watts
VEH Series
xppower.com
BRAND
⢠Energy Efficiency Level V
⢠CEC 2008 / EISA 2007 / ErP Compliant
⢠No Load Input Power <0.35 W
⢠5000 m Operating Altitude
⢠Single Outputs from 12 V to 24 V
⢠+60 º C Operating Temperature
⢠Low Cost
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
No Load Input Power
Input Protection
⢠90-264 VAC, see note 1
⢠47-63 Hz
⢠2.0 A max at 90 VAC
⢠150 A max at 230 VAC, cold start at 25 °C
⢠<500 µA at 230 VAC/50 Hz
⢠>0.95 at 230 VAC and full load
⢠<0.35 W
⢠Internal T4.0A/250 V fuse in line
General
Efficiency
Energy Efficiency
Isolation
Switching Frequency
Power Density
MTBF
⢠See table
⢠Level V
⢠3000 VAC Input to Output,
1500 VAC Input to Ground
Negative output is connected to Ground
⢠PFC: 38-380 kHz, PWM: 47-70 kHz
⢠4.5 W/in3
⢠>145 kHrs to MIL STD 217F at 25 °C GB
Output
Output Voltage
⢠See table
Initial Set Accuracy ⢠±5% at 50% load
Minimum Load
⢠No minimum load requirement
Hold Up Time
⢠8 ms typical at 115 VAC, full load
Start Up Delay
⢠3 s max
Start Up Rise Time
⢠60 ms max
Overshoot
⢠3% max
Transient Response
⢠4% maxiumum deviation, recovering to
less than 1% within 500 µs for a 50%
step load change
Line Regulation
⢠±0.5% max
Load Regulation
⢠3% max
Ripple & Noise
⢠1.5% for 12 V, 1% for 19/24 V pk-pk max,
20 MHz bandwidth (see note 2)
Overvoltage Protection ⢠See table
Overload Protection ⢠105-150%
Short Circuit Protection ⢠Continuous (hiccup/trip & restart mode
with auto recovery)
Temperature
Coefficient
⢠±0.04%/°C
Environmental
Operating Temperature ⢠0 °C to +60 °C derate linearly from 100%
load at +40 °C to 50% load at +60 °C,
Storage Temperature ⢠-20 ËC to +85 °C
Operating Humidity ⢠5% to 90% RH non-condensing
Shock
⢠6 Random drops from 0.7 m with no
damage, 50 g for 20 ms in each of 3 axes
Operating Altitude
⢠5000 m
Vibration
⢠Operating: 10-250 Hz, 1/4 g pk-pk, 3 axes,
15 min sweep
Non Operating: 10-300 Hz, 2 g pk-pk, 3
axes, 15 min sweep
Storage Humidity
⢠5% to 95% RH non-condensing
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022, level B conducted & radiated
⢠EN61000-3-2 class A,
EN61000-3-2 class C >60% load
⢠EN61000-3-3
⢠EN61000-4-2, level 3 Perf Criteria A
⢠EN61000-4-3, 3 V/m Perf Criteria A
⢠EN61000-4-4, level 2 Perf Criteria A
⢠EN61000-4-5, installation class 3,
Perf Criteria A
⢠EN61000-4-6, level 2 Perf Criteria A
⢠EN61000-4-8, 3 A/m Perf Criteria A
⢠EN55024, 100% 10 ms, 30% 500 ms,
100% 5000 ms, Perf Criteria A, A, B
⢠EN60950-1, UL/cUL60950-1
|
▷ |