VEB10US05 Datasheet, PDF (1/2 Pages) XP Power Limited – Energy Efficiency Level V | |||
|
10 Watts
VEB10 Series
BRAND
⢠Energy Efficiency Level V
⢠CEC2008 & EISA2007 Compliant
⢠+70 °C Operating Temperature
⢠Universal Input
⢠Output Voltages from 5.0 V to 48.0 V Available
⢠Class II Construction
⢠Low Cost
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Input Protection
⢠90-264 VAC
⢠47-63 Hz
⢠0.3 A max at 90 VAC
⢠80 A max at 240 VAC, cold start at 25 °C
⢠EN61000-3-2, class A
⢠<0.3 W
⢠Internal T1.0A/250 V fuse in line
Output
Output Voltage
⢠See table
Minimum Load
⢠No minimum load required
Start Up Delay
⢠3 s max
Start Up Rise Time
⢠100 ms typical
Hold Up Time
⢠5 ms typical at full load and 100 VAC
Total Regulation
⢠See table
Transient Response
⢠4% max. deviation, recovery to <1%
within 500 µs for a 50% step load change
at 0.2 A/µs
Ripple & Noise
⢠1.0% pk-pk max, 20 MHz bandwidth
Overvoltage Protection ⢠Not fitted
Overload Protection ⢠120-280%, auto recovery
Short Circuit Protection ⢠Trip and restart (hiccup mode)
Temperature
Coefficient
⢠0.04 %/°C
General
Efficiency
Energy Efficiency
Isolation
Switching Frequency
MTBF
⢠See table
⢠Level V
⢠3000 VAC Input to Output
⢠80 kHz typical
⢠>330 kHrs per MIL-HDBK-217F at 25 °C,
GB
Environmental
Operating Temperature ⢠0 °C to +70 °C, derate linearly from 100%
load at 40 °C to 50% load at 70 °C
Cooling
⢠Natural convection
Operating Humidity ⢠5-95% RH, non-condensing
Storage Temperature ⢠-40 °C to +85 °C
Shock
⢠Able to survive 1 m drop onto concrete on
each of 6 axes
Vibration
⢠10-300 Hz, 2 g 15 mins/sweep, 30 mins
for each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022, level B conducted & radiated
⢠EN61000-3-2, class A
⢠EN61000-3-3
⢠EN61000-4-2, ±4 kV contact, ±8 kV air,
Perf Criteria A
⢠EN61000-4-3, 3 V/m, Perf Criteria A
⢠EN61000-4-4, level 2, Perf Criteria A
⢠EN61000-4-5, installation class 3,
Perf Criteria A
⢠EN61000-4-6, 3 V, Perf Criteria A
⢠EN61000-4-8, 1 A/m, Perf Criteria A
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
⢠EN60950-1 for EU and UK models
UL60950-1 for US models
|
▷ |