English
Language : 

VCS50 Datasheet, PDF (1/4 Pages) XP Power Limited – 50-100 Watts VCS Series
50-100 Watts
VCS Series
xppower.com
• Chassis Mount Industrial Supplies
• -25 °C to +70 °C Convection Cooled
• Class B Conducted & Radiated Emissions
• Output Voltages from 5 V to 48 V
• <0.5 W No Load Input Power
• Low Cost
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
No Load Input Power
• 85-264 VAC (127-370 VDC),
see derating curve
• 47-63 Hz
• VCS50: 1.1 A, VCS70: 1.4 A,
VCS100: 2.0 A typical at 90 VAC
• 60 A max at 230 VAC, cold start at 25 °C
• EN61000-3-2 Class A
• 1.0 mA maximum
• 50 & 70 W: T3.15 A/250 V
100 W: T4.0A/250 V, fuse fitted in live line
• <0.5 W
Output
Output Voltage
• See model table
Output Adjust
• ±10.0%
(5 V & 12 V versions are -5% to +10%)
Initial Set Tolerance • ±1.0%
Minimum Load
• None required
Start Up Delay
• 1 s maximum
Hold Up Time
• 10 ms min at 115 VAC and full load
Line Regulation
• ±0.5%, 90 VAC to 264 VAC input
Load Regulation
• 5 V & 12 V versions: ±1%, Others: ±0.5%
0% to 100% load
Transient Response
• Less than 4% deviation with a 50% to
75% load change at 1 A/µs. Output
returns to within 1% in less than 500 µs
Ripple & Noise
• 1% maximum pk-pk, 20 MHz bandwidth
Overvoltage Protection • 120-140% of nominal output,
auto recovery
Overload Protection • 110-150% of nominal, trip and restart
Short Circuit Protection • Continuous trip and restart
Temperature
Coefficient
• ±0.03%/°C after 20 min warm up
General
Efficiency
Isolation
Switching Frequency
MTBF
• See tables
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 65 kHz typical
• >500 kHrs to MIL-STD-217F at 25 °C, GB
Environmental
Operating Temperature • -25 °C to +70 °C, see derating curve
Cooling
• Convection cooled
Operating Humidity • 0-95% R.H, non-condensing
Storage Temperature • -40 °C to +80 °C
Operating Altitude
• 3000 m
Shock
• ±3 x 30 g shocks in each plane,
30 g: 11 ms (±0.5 ms), half sine, compliant
to EN60068-2-27 & EN60068-2-47
Vibration
• 10-500 Hz at 2 g sweep and endurance at
resonance in all 3 planes. Conforms to
EN60068-2-6
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022 Class B conducted & radiated
• EN61000-3-2 class A
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
(note 3)
• EN61000-4-5, installation Class 3,
Perf Criteria A
• EN61000-4-6, level 3 Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
• IEC60950-1, CSA C22.2 No.60950-1-03,
UL60950-1, TUV EN60950-1