VCP05US05_13 Datasheet, PDF (1/2 Pages) XP Power Limited – Low Cost, Universal AC Input, Output Voltage from 5 to 15 V | |||
|
5 Watts
VCP Series
xppower.com
BRAND
⢠Low Cost
⢠Universal AC Input
⢠Output Voltage from 5 to 15 V
⢠PCB Mount
⢠Class II Construction
⢠EN55022 Class B Emissions
⢠No Load Input Power <0.3 W
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
No Load Input Power
Input Protection
⢠90-264 VAC
⢠47-63 Hz
⢠0.2 A max at 90 VAC
⢠40 A max at 240 VAC, cold start at 25 °C
⢠EN61000-3-2, class A
⢠<0.3 W
⢠Internal T1.6A/250 V fuse in line
Output
Output Voltage
⢠See table
Initial Set Accuracy ⢠±5% at 50% load
Minimum Load
⢠No minimum load required
Start Up Delay
⢠2 s max
Start Up Rise Time
⢠100 ms typical
Hold Up Time
⢠5 ms typical at full load and 115 VAC
Line Regulation
⢠±0.5% max
Load Regulation
⢠2% max, 0-100% load
Transient Response
⢠10% max. deviation, recovery to <1%
within 500 µs for a 50% step load change
at 0.2 A/µs
Ripple & Noise
⢠See table
Overvoltage Protection ⢠See table
Overload Protection ⢠120-180%, auto recovery
Short Circuit Protection ⢠Trip and restart (hiccup mode)
Temperature
Coefficient
⢠0.2 %/ËC
General
Efficiency
Isolation
Switching Frequency
MTBF
⢠See table
⢠3000 VAC Input to Output
⢠60 kHz typical
⢠250 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature ⢠0 ËC to +70 ËC, derate from 100% load at
50 °C to 50% load at 70 °C
Cooling
⢠Natural convection
Operating Humidity ⢠10-90% RH, non-condensing
Storage Temperature ⢠-20 ËC to +80 ËC
Shock
⢠Able to survive 1 m drop onto concrete on
each of 6 axes
Vibration
⢠10-300 Hz, 2 g 15 mins/sweep. 30 mins
for each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55022, level B conducted & radiated
⢠EN61000-3-2, class A
⢠EN61000-3-3
⢠EN61000-4-2, ±4kV contact, ±8kV air,
Perf Criteria A
⢠EN61000-4-3, 3 V/m, Perf Criteria A
⢠EN61000-4-4, level 2, Perf Criteria A
⢠EN61000-4-5 installation class 3,
Perf Criteria A
⢠EN61000-4-6, 3 V, Perf Criteria A
⢠EN61000-4-8, 1 A/m, Perf Criteria A
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
⢠EN60950-1, cUL60950-1, IEC60950-1
|
▷ |