English
Language : 

VCP05US033 Datasheet, PDF (1/2 Pages) XP Power Limited – Energy Star, CEC & EISA Compliant
5 Watts
VCP05 Series
xppower.com
• Energy Star, CEC & EISA Compliant
• ITE Approvals
• PCB Mount
• Class II Construction
• Compact Dimensions
• EN55022 Class B Emissions
• Low Cost
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
• 90-264 VAC
• 47-63 Hz
• 0.2 A max at 90 VAC
• 40 A max at 240 VAC
• Conforms to EN61000-3-2, class A
Output
Output Voltage
• See table
Initial Set Accuracy • ±5% at 50% load
Minimum Load
• No minimum load required
Start Up Delay
• 2 s max
Start Up Rise Time
• 100 ms typical
Hold Up Time
• 5 ms typical at full load and 115 VAC
Line Regulation
• ±0.5% max
Load Regulation
• ±5% max
Transient Response
• 10% max. deviation, recovery to <1%
within 500 µs for a 50% step load change
at 0.2 A/µs
Ripple & Noise
• See table
Overvoltage Protection • See table
Overload Protection • 120-180%, auto recovery
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
• 0.2 %/˚C
General
Efficiency
Isolation
Switching Frequency
MTBF
• See table
• 3000 VAC Input to Output
• 60 kHz typical
• 100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 ˚C to +40 ˚C
Cooling
• Natural convection
Operating Humidity • 10-90% RH, non-condensing
Storage Temperature • -20 ˚C to +60 ˚C
Shock
• Able to survive 1m drop onto concrete on
each of 6 axes
Vibration
• 10-300 Hz, 2 g 15 mins/sweep. 30 mins
for each of 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022, level B conducted & radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-2, ±4kV contact, ±8kV air,
Perf Criteria A
• EN61000-4-3, 3 V/m, Perf Criteria A
• EN61000-4-4, level 2, Perf Criteria A
• EN61000-4-5, level 3, Perf Criteria A
• EN61000-4-6, 3 V, Perf Criteria A
• EN61000-4-8, 1 A/m, Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
• EN60950, cUL60950, IEC60950
1