English
Language : 

UCP225 Datasheet, PDF (1/9 Pages) XP Power Limited – AC-DC Power Supplies
UCP225 Series
AC-DC Power Supplies
225 Watts
• Low 1.18” Profile U Channel Construction
• High Power Density
• 3.12” by 5.0” Footprint
• 150 W Convection/ 225 W Forced Cooled Ratings
• Optional 5 V Standby and Remote On/Off
• 12 V Fan Output
• Medical and ITE Approvals
• High Efficiency, up to 95%
• Less than 0.5 W No Load Input Power
The UCP225 series is designed to minimize the no load power consumption and maximize efficiency Dimensions:
to facilitate equipment design to meet the latest environmental legislation. Approved for medical and
ITE applications, this range of single output AC/DC power supplies are packaged in an ultra-low
UCP225:
5.00 x 3.12 x 1.18” (127.0 x 79.2 x 29.2 mm)
profile 1.18” height with a foot print of just 3.12” by 5.0”. The UCP225 provides up to 225 W force-
cooled or 150 W convection-cooled leading to very high power densities of 12.2 W/in3 or 8.1 W/in3 respectively. A 12 V, 500 mA fan supply is
included in the design which can also be delivered with an optional 5 V/2 A standby output. The power supply contains two fuses and low
leakage currents as required by medical applications and is safety approved to operate in a 70 °C ambient. The low profile and safety approvals
covering ITE and medical standards along with conducted emissions to EN55011/22 level B allow the versatile UCP225 series to be used in a
vast range of applications.
Models & Ratings
Output
Voltage
12.0 V
15.0 V
24.0 V
28.0 V
48.0 V
Output Current
Convection-cooled Forced-cooled(1)
12.50 A
18.75 A
10.00 A
15.00 A
6.25 A
9.38 A
5.36 A
8.04 A
3.10 A
4.69 A
Optional Standby Output
Convection-cooled
Forced-cooled(1)
5 V/1.0 A
5 V/2.0 A
5 V/1.0 A
5 V/2.0 A
5 V/1.0 A
5 V/2.0 A
5 V/1.0 A
5 V/2.0 A
5 V/1.0 A
5 V/2.0 A
Fan Output
12 V/0.5 A
12 V/0.5 A
12 V/0.5 A
12 V/0.5 A
12 V/0.5 A
Efficiency(2)
92%
92%
92%
92%
92%
Model Number(3, 4, 5, 6)
UCP225PS12
UCP225PS15
UCP225PS24
UCP225PS28
UCP225PS48
Notes
1. Requires 10 CFM or optional top fan cover, -TF
2. Minimum average efficiencies measured at 25%, 50%, 75% & 100% of 225 W
load and 230 VAC input
3. Add suffix -T for input and output screw terminals e.g. UCP225PS24-T
4. Add suffix -TF for fan cover version e.g. UCP225PS24-TF
5. Add suffix -C for vented cover version e.g. UCP225PS24-C
6. Add suffix -A for optional 5 V, 2 A standby and remote on/off e.g. UCP225PS24-A
Input
Characteristic
Input Voltage - Operating
Input Frequency
Power Factor
Input Current - Full Load
Inrush Current
Earth Leakage Current
No load Input Power
Input Protection
Minimum
Typical
Maximum
85
115/230
264
47
50/60
63
>0.9
2.2/1.1
120
80/140
230
0.5
F3.15 A/250 V Internal fuse fitted in line and neutral.
Units
VAC
Hz
A
A
µA
W
Notes & Conditions
Derate output from 100% at 90 VAC to 90% at 85 VAC
230 VAC, 100% load. EN61000-3-2 class A, class C >145W
115/230 VAC
230 VAC cold start, 25 ºC
115/230 VAC/50 Hz (Typ), 264 VAC/60 Hz (Max)
When main output is Inhibited
1