SWX1048S1V2 Datasheet, PDF (1/4 Pages) XP Power Limited – DC-DC Power Supplies | |||
|
10-30 Watts
SWX Series
xppower.com
⢠Low Profile (8 mm max)
⢠Wide Operating Temperature
⢠Remote On/Off
⢠Parallel Operation
⢠High Reliability
⢠International Safety Approvals
Specification
Input
Input Voltage Range
Start Up Voltage
Hysteresis Voltage
⢠18-36 VDC (for SWX15 & SWX30)
36-76 VDC
⢠16-18 VDC for 24 Vnom
32-36 VDC for 48 Vnom
⢠1 VDC min for 24 Vnom
2 VDC min for 48 Vnom
Output
Output Voltage
⢠See table
Minimum Load
⢠No minimum load required
Start Up Delay
⢠200 ms max (Vnom, Io 100%)
Initial Set Accuracy
⢠Vnom +2/-1% measured at Vnom in 100%
load and +25 ºC
Total Regulation
⢠+5/-3%
Output Ripple
⢠25 mV max pk-pk, 1.2 to 5 V models
120 mV max 12 & 15 V models
Ripple & Noise
⢠50 mV pk-pk, 1.2 to 5 V models
150 mV max 12 & 15 V models
Overvoltage Protection ⢠120-140% of Vnom recycle input to reset
Low Voltage Protection ⢠Works 200 ms after an overload when the
output voltage drops to 90% of rating
Remote On/Off
⢠Standard
Parallel Operation
⢠It is possible to parallel a maximum
of 10 units
General
Efficiency
Isolation Voltage
Alarms
⢠See table
⢠Input to Output 1500 VDC
⢠If over or under voltage protection is
activated the ALM pin becomes the same
level as the -Vin pin
Environmental
Operating Temperature ⢠-40 ºC to +85 ºC (for derating curves
- contact sales for application note)
Storage Temperature ⢠-40 ºC to +100 ºC
Operating Humidity ⢠20-90%, RH non-condensing
Shock
⢠20 G, 11 ms once each X, Y & Z axis
Vibration
⢠5 G 10-55 Hz 3 min period, 60 min each
along X, Y & Z axis
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Safety Approvals
⢠EN55022, level A conducted
external filter required
EN55022, level A radiated
(contact sales for application note)
⢠EN61000-4-2, level 4
⢠EN61000-4-3, level 3
⢠EN61000-4-4, level 4
⢠EN61000-4-5, level 3
⢠EN60950, UL60950, C-UL
|
▷ |