SMQ300PS12-C Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Power Supplies | |||
|
300/400 Watts
SMQ Series
xppower.com
⢠High Power Density
⢠High Peak Load Rating
⢠DC OK
⢠Remote On/Off
⢠Universal Input
⢠Single Outputs from 12.0 V to 54.0 V
⢠Internal Fan
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
⢠90-264 VAC (120-370 VDC)
⢠47-63 Hz
⢠5.00 A at 90 VAC (SMQ300),
6.35 A at 90 VAC (SMQ400)
⢠35 A max at 230 VAC
⢠0.99 typical
⢠<2.5 mA at 230 VAC/50Hz
<1.5 mA at 115 VAC/60Hz
Output
Output Voltage
⢠12 to 54 VDC - see table
Output Voltage Trim ⢠See table
Minimum Load
⢠No minimum load required
Start Up Delay
⢠2.5 s typical at 120 VAC
Hold Up Time
⢠20 ms minimum at 120 VAC & 80% load
Line Regulation
⢠±1%
Load Regulation
⢠±1%
Transient Response
⢠5% max. deviation, recovery to within
1% in 500 µs for a 50% load change
Ripple & Noise
⢠1% pk-pk, 20 MHz BW
Overvoltage Protection ⢠115-130% Vnom, recycle input to reset
Overcurrent Protection ⢠120-150% of nominal current,
auto recovery
Overtemperature
Protection
⢠Unit shuts down, auto recovery
Remote Sense
⢠Compensates for up to 0.5 V drop
Remote On/Off
⢠On = TTL Logic High or Open circuit
Off = TTL Logic Low or Short circuit
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
⢠80% typical
⢠3000 VAC Input to Output,
1500 VAC Input to Ground,
250 VDC Output to Ground
⢠60 kHz typical for PFC stage,
30 kHz typical for main converter
⢠4.7 W/In3 (SMQ300), 6.25 W/In3 (SMQ400)
⢠DC OK, TTL HIGH within 100-500 ms
LOW 1 ms before loss of regulation
⢠138 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature ⢠0 ËC to +70 ËC, derate linearly from
100% at +50 ËC to 50% at +70 ËC
Cooling
⢠Via internal fan
Operating Humidity ⢠5-90% RH, non-condensing
Storage Temperature ⢠-20 ËC to +85 ËC
Shock
⢠15 g (non-operation), 11 ms half
sine-wave, 3 times for each axis
Vibration
⢠10 Hz - 55 Hz (non-operation) 2 g,
sweep time 3 mins, 60 mins/axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55022 and FCC Part 15,
level B conducted
⢠EN61000-3-2
⢠EN61000-3-3
⢠EN61000-4-2, level 2 contact, level 3 air,
Perf Criteria A
⢠EN61000-4-3, 3 V/m, Perf Criteria A
⢠EN61000-4-4, level 2, Perf Criteria A
⢠EN61000-4-5, level 3, Perf Criteria A
⢠EN61000-4-6, level 2, Perf Criteria A
⢠EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
⢠UL60950, CSA C22.2 No.60950,
EN60950, CE Mark LVD
|
▷ |