English
Language : 

SML150PS12 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Power Supplies
150-300 Watts
SML Series
xppower.com
• Small Size - 4” x 6” Footprint
• Single Outputs 12-54 VDC
• High Power Density
• 150 W Convection-cooled
• 300 W Fan-cooled
• Temperature-controlled Fan
• PFD & Fan Fail Signals
Specification
Input
Input Voltage
• 90-132 / 180-264 VAC autoranging
Input Frequency
• 47-63 Hz
Input Current
• 6.30/3.15 A at 115/230 VAC
Inrush Current
• 70 A max at 230 VAC, cold start
Power Factor
• Complies with EN61000-3-2 Class A
Earth Leakage Current • 3.5 mA max at 230 VAC
Input Protection
• Internal 6.3 A / 250 VAC fuse
Output
Output Voltage
• See tables
Output Voltage Trim • ±5%
Minimum Load
• See tables
Initial Set Accuracy • ±1%
Start Up Delay
• 1 s max
Start Up Rise Time
• 20 ms min at 120 VAC
Hold Up Time
• 20 ms min at 120 VAC & 80% load
Total Regulation
• ±1%
Over/Undershoot
• 5% max at turn on/off
Transient Response
• 5% max. deviation, recovery to within
1% in 500 µs for a 50% load change
Ripple & Noise
• 1% pk-pk, 20 MHz BW, see note 1
Overvoltage Protection • <130% Vnom, recycle input to reset
Overtemperature
Protection
• Unit shuts down with auto recovery,
measured internally
Overload Protection
• 110-140%, trip & restart (Hiccup mode)
with auto recovery
Fan Output
• 12 VDC at 500 mA, temperature-controlled
(available on 150 W model only)
Aux Output
• 12 VDC at 500 mA (12.0-14.5 VDC)
General
Efficiency
Isolation
Switching Frequency
Power Density
PFD
Signals
MTBF
• 75% minimum, 230 VAC 100% load
• 3000 VAC Input to Output
1500 VAC Input to Ground
250 VDC Output to Ground
• 30 kHz typical
• Up to 6.25 W/In3
• Open collector signal is LOW when
DC is OK
• Green LED to indicate power on
• 100 kHrs per MIL-HDBK-217F at +30 °C
Environmental
Operating Temperature • -20 °C to +70 °C, derate from +50 °C at
2.5%/°C
Cooling
• 150 W convection-cooled,
300 W with internal fan
Operating Humidity • 5-90% RH, non-condensing
Storage Temperature • -20 °C to +85 °C
Operating Altitude
• 3000 m
Vibration
• 5-50 Hz, 7.35 ms2 on X,Y & Z axis
EMC & Safety
Emissions
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Safety Approvals
• EN55022, level B conducted
FCC Part 15 Subject J Class B
• EN61000-3-3 amendments 1 & 2
• EN61000-4-2, level 2 Contact, Level 3
• EN61000-4-3, level 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 3 V Perf Criteria A
• EN60950-1, UL60950-1,
CSA22.2 No 60950-1