SHP-SERIES Datasheet, PDF (1/5 Pages) XP Power Limited – 3501200 Watts | |||
|
350 1200 Watts
SHP Series
xppower.com
⢠Rugged Industrial Construction
⢠Variable Fan Speed for Noise Reduction
⢠40 °C to +70 °C Operation
⢠AC OK, Remote On/Off and Active Current Share
⢠5 V Standby
⢠Screw Terminals
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
Output
⢠650 W: 80-264 VAC, derate output power
10% <90 VAC, and 20% <85 VAC
350 & 1000 W: 85-264 VAC, derate output
power 10% <90 VAC
⢠47-63 Hz
⢠350 W: 3.8 A typical at 115 VAC,
2.1 A typical at 230 VAC,
650 W: 6.5 A typical at 115 VAC,
3.2 A typical at 230 VAC,
1000 W: 10.9 A typical at 115 VAC,
5.1 A typical at 230 VAC
⢠650 W: 40 A max at 264 VAC
350 & 1000 W: 60 A max at 264 VAC
⢠>0.9
⢠0.5 mA max 264 VAC/60 Hz(1)
⢠350W: T10 A/250 V, 650W: T16 A/250 V,
1000W: T20 A/250 V internal fuse in line and
neutral, 350W: single internal fuse in line.
Output Voltage
⢠12-48 VDC (see tables)
Output Voltage Trim ⢠±10% V1
Initial Set Accuracy
⢠650 W: ±1% V1, ±5% V3,
350 & 1000 W: ±1% V1, ±5% V2
Minimum Load
⢠No minimum load required
Start Up Delay
⢠500 ms max
Start Up Rise Time
⢠50 ms typical
Hold Up Time
⢠20 ms minimum
Drift
⢠±0.2% after 20 min warm up
Line Regulation
⢠±0.5%
Load Regulation
⢠650 W: ±1% V1, ±5% V3,
350 & 1000 W: ±1% V1, ±5% V2
Transient Response
⢠4% max. deviation, recovery to
within 1% in 500 µs for a 50-75-50%
load change
Ripple & Noise
⢠1% pk-pk typical V1, 20 MHz bandwidth
Overvoltage Protection ⢠115-145% Vnom, recycle input to reset
Overload Protection ⢠110-140%, V1 only
Overtemperature
Protection
⢠Auto reset
Short Circuit Protection ⢠Constant current characteristic (1)
Temp. Coefficient
⢠0.05% / °C
Remote Sense
⢠Compensates for 0.5 V total voltage drop
Remote On/Off
⢠Uncommitted isolated optocoupler diode,
powered diode inhibits V1 and fan supply (1)
Current Share
⢠Single wire current share (1)
(1) See longform datasheet for more information
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
⢠85% typical
⢠3000 VAC input to output, 1500 VAC input
to ground, 500 VDC output to ground
⢠PFC 70 kHz, main converter 200 kHz,
standby 130 kHz typical
⢠350 W: 6.6 W/in3, 650 W: 8.2 W/in3,
1000 W: 8.9 W/in3
⢠AC OK, remote on/off, current share (1)
⢠216-275 KHrs to MIL-HDBK-217F at 25 °C,
GB(1)
Environmental
Operating Temperature ⢠-20 °C to +70 °C, derate linearly from
+50 °C at 2.5% / °C to 50% at +70 °C,
-40 °C start up (1)
Cooling
⢠650 W: Forced cooled, â-TFâ & â-EFâ models
have integral dual voltage level fan, which is
load dependant, U Channel requires 5.5 m/s
minimum airflow, 350 & 1000 W: Forced cooled
via integral multi voltage level fan which is load
dependant (1)
Operating Humidity ⢠95% RH, non-condensing
Storage Temperature ⢠-40 °C to +85 °C
Operating Altitude
⢠3000 m
Shock
⢠30 g pk, half sine, 6 axes EN60068-2-27, -2-47
Vibration
⢠2 g rms, 5-500 kHz, 3 axes EN60068-2-6
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55022 class B conducted
EN55022 class A radiated
⢠EN61000-3-2 class A,
650 W: class C for loads â¥20%
350 & 1000 W: class C for loads â¥10%
⢠EN61000-3-3
⢠EN61000-4-2, level 3 contact, level 3 air,
Perf Criteria A
⢠EN61000-4-3, level 3 Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
⢠EN61000-4-5, installation class 3,
Perf Criteria A
⢠EN61000-4-6, level 3, Perf Criteria A
⢠EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
⢠IEC60950-1 CB report, CSA 22.2
No. 60950-1, UL60950-1, TUV,
EN60950-1, SEMI F47
|
▷ |