SDS60US03 Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Power Supplies
60 Watts
SDS60 Series
xppower.com
• Single, Dual, Triple & Quad Outputs
• Output Voltages from 3.3 V to 48 V
• Non-standard Outputs Available
• Universal AC Input
• Low Profile - 1.2” (30.5 mm)
• Fits 1U Applications
• Up to 88% Efficiency
Specification
Input
Input Voltage
• 90-264 VAC (120-370 VDC)
Input Frequency
• 47-63 Hz
Input Current
• 1.6 A at 115 VAC
1.0 A at 230 VAC
Inrush Current
• <15 A at 115 VAC
<30 A at 230 VAC
Earth Leakage Current • <0.30 mA at 115 VAC
<0.75 mA at 230 VAC
Input Protection
• 2 A/250 VAC internal fuse
Output
Output Voltage
• See table
Output Voltage Trim • ±10% on V1 only (see note 4)
Initial Set Accuracy
• Single output models: ±1%
Multi-output models: ±5%
Minimum Load
• 10% required on V1 & V2 of multi-output
models to maintain regulation, unit will
start up with no load
Start Up Delay
• 1 s typical
Hold Up Time
• 12 ms min at 110 VAC, 100% load
Line Regulation
• 1% from low line to high line
Load Regulation
• 5% max all models, ±10% with no load
on V1 - see table
Transient Response
• 4% max deviation, recovery to within
1% in 4 ms for a 50% load change
Ripple & Noise
• 1% pk-pk typical, 20 MHz BW
Overvoltage Protection • 112-132%, recycle input to reset
Overload Protection • All outputs 110-150% with auto recovery
Short Circuit Protection • Trip & restart (Hiccup mode),
auto recovery
Temperature
Coefficient
• 0.04%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
• 80% typ, 88% max, 230 VAC 100% load
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 60 kHz typical
• 3.5 W/In3
• Green DC OK LED
• >100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate linearly from 100%
load at +40 °C to 50% load at +70 °C
Cooling
• Convection-cooled
Operating Humidity • 5-95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022, FCC Part 15, level B conducted
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-8, 1 A/m Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
• EN60950-1, UL60950-1,
CSA60950-1 per cUL, CE Mark LVD