SDS60 Datasheet, PDF (1/2 Pages) XP Power Limited – 60 Watts SDS Series
60 Watts
SDS Series
xppower.com
• Single, Dual, Triple & Quad Outputs
• Output Voltages from 3.3 V to 48 V
• Non standard Outputs Available
• Industry Standard 3” x 5” Package
• Fits 1U Applications
• Open Frame, U Channel & Covered Versions
• 3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
Power Factor
Input Protection
• 90-264 VAC (120-370 VDC)
• 47-63 Hz
• 1.6 A max at 115 VAC
1.0 A max at 230 VAC
• <15 A at 115 VAC, cold start at 25 °C
<30 A at 230 VAC, cold start at 25 °C
• <0.30 mA at 115 VAC
<0.75 mA at 240 VAC
• EN61000-3-2, Class A
• T2 A/250 VAC internal fuse in line
Output
Output Voltage
• See table
Output Voltage Trim • ±10% on V1 only (see note 4)
Initial Set Accuracy
• Single output models: ±1%
Multi-output models: ±5%
Minimum Load
• 10% required on V1 & V2 of multi-output
models to maintain regulation, unit will
start up with no load
Start Up Delay
• 2 s typical
Hold Up Time
• 12 ms min at 110 VAC, 100% load
Line Regulation
• 1% from low line to high line
Load Regulation
• 7% max all models 3% typical, see table
10% with no load on V1, for multi output
models
Transient Response
• 4% max deviation, recovery to within
1% in 4 ms for a 50% load change
Ripple & Noise
• 1% pk-pk typical, 20 MHz bandwidth
Overvoltage Protection • 112-132% of nominal output voltage on
V1 only, recycle input to reset
Overload Protection
• 110-150% of nominal power,
with auto recovery
Short Circuit Protection • Trip & restart (hiccup mode),
auto recovery
Temperature
Coefficient
• ±0.04%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
• 80% typical, 230 VAC full load
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
• 60 kHz typical
• 3.5 W/In3
• Green DC OK LED
• 190 kHrs typical to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature • 0 °C to +70 °C, derate linearly from 100%
load at +50 °C to 50% load at +70 °C
Cooling
• Convection-cooled
Operating Humidity • 5-95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
• EN55022, level B conducted and radiated
• EN61000-3-2, Class A
• EN61000-3-3
• EN61000-4-2, level 2 contact, level 3 air,
Perf Criteria A
• EN61000-4-3, level 2, Perf Criteria A
• EN61000-4-4, level 2, Perf Criteria A
• EN61000-4-5, installation Class 3,
Perf Criteria A
• EN61000-4-6, level 2, Perf Criteria A
• EN61000-4-8, 1 A/m, Perf Criteria A
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
• EN60950-1, UL60950-1,
CSA60950-1 per cUL