SDS120PS03B Datasheet, PDF (1/2 Pages) XP Power Limited – AC-DC Power Supplies | |||
|
120 Watts
SDS120 Series
xppower.com
⢠Single, Dual & Triple Outputs
⢠Convection-cooled
⢠3â x 5â Footprint
⢠High Efficiency to 85%
⢠Open Frame, U-Channel & Covered Versions
⢠Low Temperature Option
⢠Optional Power Fail Detect Signal
Specification
Input
Input Voltage
⢠90-264 VAC (120-370 VDC)
Input Frequency
⢠47-63 Hz
Input Current
⢠1.7 A at 115 VAC
1.0 A at 230 VAC
Inrush Current
⢠<30 A at 115 VAC
<55 A at 230 VAC
Power Factor
⢠0.97 typical
Earth Leakage Current ⢠<0.30 mA at 115 VAC
<0.75 mA at 230 VAC
Input Protection
⢠3.15 A on board fuse
Output
Output Voltage
⢠See table
Output Voltage Trim ⢠±5% output 1 only (3.3 V variant ±10%)
Initial Set Accuracy
⢠Single output models: ±1%
Multi-output models: ±5%
Minimum Load
⢠No minimum load required for single
output models. For multi-output models
see table.
Start Up Delay
⢠2 s max
Start Up Rise Time
⢠2 ms
Hold Up Time
⢠>16 ms
Line Regulation
⢠1% maximum, ±0.5% typical
Load Regulation
⢠5% maximum, ±3.0% typical
Transient Response
⢠4% max deviation, recovery to within
1% in 4 ms for a 50% load change
Ripple & Noise
⢠1% pk-pk typical, 20 MHz BW
Overvoltage Protection ⢠112-132% V1 only, recycle input to reset
Overload Protection
⢠All outputs: 110-150% with auto recovery
(primary power limit)
Short Circuit Protection ⢠Trip & restart (Hiccup mode),
auto recovery
Temperature
Coefficient
⢠0.04%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
⢠80% typical, 85% max,
230 VAC 100% load
⢠3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
⢠PFC 100 kHz, PWM 67 kHz
⢠4.87 W/In3
⢠Power Fail Detect = TTL active low,
combined AC and DC OK signal (option)
⢠>100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature ⢠0 °C to +70 °C, derate linearly from 100%
load at +50 °C to 50% load at +70 °C,
low temperature option â-Lâ -40 °C
Cooling
⢠Convection-cooled
Operating Humidity ⢠5-95% RH, non-condensing
Storage Temperature ⢠-40 °C to +85 °C
Vibration
⢠2 g on 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
⢠EN55022, CISPR22 and FCC, part 15
level B conducted
⢠EN61000-3-2
⢠EN61000-3-3
⢠EN61000-4-2, level 2 Perf Criteria A
⢠EN61000-4-3, 3 V/m Perf Criteria A
⢠EN61000-4-4, level 2 Perf Criteria A
⢠EN61000-4-5, level 3 Perf Criteria A
⢠EN61000-4-6, level 2 Perf Criteria A
⢠EN61000-4-11, 30% 10 ms,
60% 100 ms, >95% 5000 ms
Perf Criteria A, B, B
⢠EN60950-1, UL60950-1,
CSA60950-1 per cUL, CE Mark LVD
|
▷ |