Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
• 90-264 VAC
• 47-63 Hz
• 6 A at 90 VAC, 2.5 A at 230 VAC
• Max 70 A at 230 VAC, 35 A at 115 VAC,
cold start
• EN61000-3-2 class A, >0.9
• <1.5 mA at 264 VAC, option ‘-L’ 500 µA
at 240 VAC
• T8 A/250 V fuse
Output
Output Voltage
• See tables
Output Voltage Trim
• ±5% on V1 (V2 of dual output models will
track by same % of adjustment)
Initial Set Accuracy • ±1%
Minimum Load
• 1% on single output models,
10% on both output of dual output models
in order to maintain ripple & noise and
regulation specifications
Start Up Delay
• 1.5 s max at 115 VAC
Start Up Rise Time
• 50 ms typical
Hold Up Time
• 16 ms min at 75% of full load at 115 VAC
Line Regulation
• ±0.5%
Load Regulation
• ±1% for single outputs,
±3% V1, ±7% V2 for dual outputs
(except PD0512 version: ±5% on V1 and
±10% on V2)
Over/Undershoot
• 5% max
Transient Response
• ±5% max deviation, recovery to within
1% in 500 µs for a 50% load change
Ripple & Noise
• 1% pk-pk (see note 3)
Overvoltage Protection • <130% on V1 recycle AC input to reset
Overload Protection • 110-140%
Short Circuit Protection • Trip & restart, auto recovery
Fan Supply
• <5V at 300mA with 1% load rising to 12-
13 V at 300mA with full load. Not available
on ‘-F’ & ‘-E’ versions with built-in fans
Remote On / Off
• Applying short circuit between inhibit pin
and signal return turns output off.
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
• Single output: 88% typical
Dual Output: 85% typical at 230 V & full
load
• 3000 VAC Input to Output, 1500 VAC
Input to Ground, 250 VDC Output to
Ground
• PFC, 68 kHz PFC, PWM: 55 kHz for single
output, & PD1224, 48 kHz for other parts.
• 11.11 W/In3
• Fan Fail & Power Good
• >100 kHrs to MIL-HDBK-217F,
at 25 °C GB
Environmental
Operating Temperature • 0 °C to +70 °C, derate at 2.5%/°C from
+50 °C to +70 °C
Storage Temperature • -20 °C to +85 °C
Operating Humidity • 5-90%, non-condensing
Cooling
• ‘-F’ & ‘-E’ versions have built-in variable
speed fans, all other models require 15
CFM
Operating Altitude
• 3000 m
Vibration
• 5-50 Hz, acceleration 7.35 ms2 on 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022 Level B conducted & radiated
• EN61000-3-2 class A
EN61000-3-2 class C for loads ≥30%
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, installation class 3
Perf Criteria A
• EN61000-4-6, 3V Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
• UL60950-1, CSA C22.2 No. 60950-1,
EN60950-1